Subject to change · Filter Unit FAPC 016 · 1020 · EN
Page 31
www.argo-hytos.com
Fig. 16: Device dimensions
16. Technical data
16.1
Dimensions
16.2
Technical data
Nominal flow rate
l/min (50 Hz)
l/min (60 Hz)
16
19.2
Pressure limiting valve
bar
5 ± 0.5
Max. operating pressure
bar
4
Filter element
V7.1220-113 ß
5
(c)
≥ 200
Clogging indicator
Pressure gauge DG 200-17
green: 0 - 2.7 bar
red: from 2.7 bar onwards
Suction side
Hose DN 20 with suction strainer
Pressure side
Hose DN 20 with discharge pipe
Suction strainer
Filter element 280 µm
Electric drive
1phase 230 V Motor
230 V; 50 Hz; 0.45 kW
230 V; 60 Hz; 0.54 kW
Tare weight
kg
approx. 24
Sound power level
db(A) max.
68 (under operating conditions permitted for continuous operation)
Table 7: Technical data