Subject to change · Filter Unit FAPC 016 · 1020 · EN
Page 19
www.argo-hytos.com
10.2.1 Replacing the suction strainer
NOTE
Damage to the filter unit by missing or defective suction strainer.
Property damage
›
The suction strainer must be regularly checked and replaced if necessary, according to the maintenance intervals.
Fig. 6: Replacing the suction strainer
1. Loosen the hose clamp (1).
2. Pull the suction hose (2) from the suction strainer (3).
3. Clean the suction strainer (3) with benzine or diesel fuel.
4. Push the suction hose (2) - as shown above - onto the suction strainer (3).
5. Attach the hose clamp (1).
NOTE
›
In case of damage, replace the suction strainer (3) (Order No. FA 016.0100).
10.3
Replacing the filter element
1. Pump the filter element dry (see chapter 9.2 “Filtering liquids in the bypass flow“ Point 7).
2. Turn the filter unit off at the on/off switch (circuit breaker) and pull the mains plug.
CAUTION
Risk of burns
Contact temperatures according to DIN EN563 (3) and DIN EN13202 (4) may be exceeded during
operation.
›
Allow the filter unit to cool down before touching it.