ACE-SXC Manual
page 57
rev2.02
SR[0,1]
Description:
Write:
Set the standalone control for the specified standalone program
Syntax:
Write:
SR[0,1] = [0-3]
SR[0,1] = [0-3]
Examples:
IF DI1=1
; If digital input 1 is on
SR0=0
; Turn off standalone program 0
ENDIF
STORE
Description:
Command:
Store all values to flash
Syntax:
STORE
Examples:
V40=PX
;***Put position value in V40
DELAY=1000
;***Wait 1 second
STORE
;***Store V40 to non-volatile flas
SUB
Description:
Indicates start of subroutine
Syntax:
SUB [subroutine number]
[Subroutine Number] range is 0 to 31
Examples:
GOSUB 1
END
SUB 1
X0
WAITX
X1000
WAITX
ENDSUB