Figure 5.5
1.
Target Position/Speed/Accel
Position – Set the target position. This position is the pulse position
HSPD/LSPD – Set the speed of the move. This value is in pulses/second
ACC – Set the acceleration/deceleration of the move. This value is in
milliseconds
2.
Set Position –
Set position counter to the Target
Position value.
3.
ABS Mode
– Set to absolute move mode. In ABS mode, all position
moves go directly to the target position
4.
INC Mode
– Set to incremental move mode. In INC mode, all moves
increment/decrement from the current position
5.
DATUM
– Absolute move to zero position. Maximum delta from current
position to target is 262,143. If greater, then move will not perform
6.
ABS
– Absolute move to target position. Maximum delta from current
position to target is 262,143. If greater, then the move will not perform
7.
JOG+/-
- Jog in plus or minus direction
8.
HOME+/-
- Homing in plus or minus direction
9.
HL+/-
- Low speed homing in the plus of minus direction
10.
L+/-
- Limit homing in the plus or minus direction
11.
ISTOP
– Immediate stop without deceleration
12.
RSTOP
– Stop with deceleration
1
2
3
4
5
6
7
8
9
10
11
12
Summary of Contents for ACE-SXC
Page 1: ...ACE SXC Manual page 1 rev2 02 ACE SXC Advanced Stand Alone Controller USB 2 0 communication...
Page 8: ...ACE SXC Manual page 8 rev2 02 3 Dimensions Figure 3 0 All dimensions in inches...
Page 9: ...ACE SXC Manual page 9 rev2 02 4 Connections Figure 4 0...
Page 12: ...ACE SXC Manual page 12 rev2 02 ACE SXC Interface Circuit Figure 4 4...