Digital Inputs
ACE-SXC module comes with 3 digital inputs. If the limit/alarm function is disabled, up
to 8 inputs can be used as general purpose inputs
Read digital input status using the
DI
command. See description below:
Digital input values can also be referenced one bit at a time by the
DI[1-8]
commands.
Note that the indexes are 1-based for the bit references (i.e. DI1 refers to bit 0, not bit 1)
Bit
Description
Bit-Wise
Command
0
Digital Input 1
DI1
1
Digital Input 2
DI2
2
Digital Input 3
DI3
3
Configuration Button
DI4
4
Minus Limit
DI5
5
Home
DI6
6
Plus Limit
DI7
7
Alarm
DI8
Table 6.1
Digital inputs are active high.
Digital Outputs
ACE-SXC module comes with 2 digital outputs.
Read and set digital output status using the
DO
command. See description below:
Bit
Description
Bit-Wise
Command
0
Digital Output 1
DO1
1
Digital Output 2
DO2
Table 6.2
Digital output values can also be referenced one bit at a time by the
DO[1-2]
commands.
Note that the indexes are 1-based for the bit references (i.e. DO1 refers to bit 0, not bit 1)
The initial state of both digital outputs can be defined by setting the
DOBOOT
register to
the desired initial digital output value. The value is stored to flash memory once the
STORE
command is issued.
Digital outputs are active low.
Summary of Contents for ACE-SXC
Page 1: ...ACE SXC Manual page 1 rev2 02 ACE SXC Advanced Stand Alone Controller USB 2 0 communication...
Page 8: ...ACE SXC Manual page 8 rev2 02 3 Dimensions Figure 3 0 All dimensions in inches...
Page 9: ...ACE SXC Manual page 9 rev2 02 4 Connections Figure 4 0...
Page 12: ...ACE SXC Manual page 12 rev2 02 ACE SXC Interface Circuit Figure 4 4...