Power Input
Figure 4.5 shows that the power and ground signals that are supplied to ACE-SXC
through the 2 pin connector are also available through the DB9 pin connector.
Regulated Supply Voltage Range:
+12 to 48 VDC
Recommended Current for power supply:
†
200 mA
† If driver is powered through the DB-9, additional current is required to power the
driver.)
Figure 4.5
WARNING:
If the driver is powered through the DB9 connector, make sure that the
voltage of the power supply does not go over the maximum rated power supply voltage
of the driver. For example, DMX-K-DRV maximum allowed voltage is +24VDC. If
ACE-SXC is powered by +48VDC, powering the DMX-K-DRV through the DB9
connector will damage the driver.