DI[1-8]
Description:
Read:
Gets the digital input value. ACE-SXC has 8 digital inputs.
Digital inputs are active high
Syntax:
Read:
[variable] = DI[1-8]
Conditional:
IF DI[1-8]=[variable]
ENDIF
IF DI[1-8]=[0 or 1]
ENDIF
Examples:
IF DI1=0
DO=1
;***If digital input 1 is triggered, set DO=1
ENDIF
DO
Description:
Read:
Gets the digital output value
Write:
Sets the digital output value
ACE-SXC has 2 digital outputs.
Digital outputs are active low.
Syntax:
Read:
[variable] = DO
Write:
DO = [value]
DO = [variable]
Conditional:
IF DO=[variable]
ENDIF
IF DO=[value]
ENDIF
Examples:
DO=3
;***Turn on both bits