Section 5. Troubleshooting
2192-08270-000-000
Section 5. Troubleshooting
J539 TARGET386EX
Page 27
Problem
Suggestions
No monitor sign-
on message on
terminal when
running with SVIF1
Cant access dual
port RAM from
STEbus
Cant access
STEbus peripheral
board
Cant access PC/104
peripheral board
Check connections to correct COM port
Check links in default positions especially LK19
(should be fitted)
Check baud rate, stop bits and parity of terminal
Check power on board - red surface mount LED
should be lit
Check base address and DPR size selection on
LK7, LK4 and LK5
Check board is in STEbus slave mode (General
control register 1)
Check no other boards in system use same
STEbus Memory window as DPR
Check TARGET386EX is not in reset state
Check board is in default or potential master
mode. If in potential master mode check that
there is an STEbus default master in the system
to do the bus arbitration
Check that SYSRST* is being driven on power-
up by one board only in the system
Check that SYSCLK* is being driven by only one
board in the system
Check that STEbus address range being accessed
is available off-board (is it covered by one of the
on-board memory or peripheral chip selects)
•
Is the STEbus the default bus (see General
Control Register 1), if not check that at least one
of chip selects CS3-6 been set up to cover the
required address range
•
Is the address range being accessed available to
the PC/104 bus - is it covered by one of the on-
board peripheral chip selects
•
Is PC/104 the default expansion bus (see General
Control Register 0), if not check that at least one
of the chip selects CS3-6 has been set up to cover
the required address range
Is the PC/104 board correctly plugged on to
the board