Programmable Pulse: Seconds-Per-Pulse Mode
Use the “SEC. PER PULSE?” mode to generate a pulse every X number of seconds, from 1 to 60,000
seconds (16+ hours), and a Pulse Width of from 10 milliseconds to 600 seconds. Pulse Polarity
marked (+) starts at a logic low and transitions high. Pulse Polarity marked (–) starts at a logic
high and transitions low. Refer to Section 8.8 above for additional detail on the Programmable
Pulse settings.
For RS-232 commands, see Section 11.2.10
SET PROG. PULSE?
ENTER
SETUP
MODE
SECONDS PER PULSE
DOWN
UP
ENTER
PULSE WIDTH
000.01
DOWN
UP
ENTER
600.00
|
000.01*
SECONDS PER PULSE
00001
DOWN
UP
ENTER
60000
|
00001*
TIME
UTC
DOWN
UP
ENTER
LCL
UTC*
* = Default Setting
PULSE POLARITY
(+)
DOWN
UP
ENTER
(–)
(+)*
SLOW CODE
SINGLE TRIGGER
IRIG-B
PULSE PER DAY
PULSE PER HOUR
SECONDS PER PULSE*
PROG. PULSE OFF
DCF77
DCF77 modified
Figure 8.10: Seconds-Per-Pulse Setup