92
RS-232C Command Set
Broadcast Data: ABB SPA MSG
Command:
0,nTB
Starts the ABB SPA broadcast from the COM port that received the request.
Format:
n = time format: 0 = UTC, 1 = local
Response:
>
900WD:yy-mm-dd hh:mm:ss.fff:cc
<
CR
>
Where:
>
900WD: = beginning of string
yy
= year of century, (00. . . 99)
mm
= month, (1. . . 12)
dd
= day of month, (01. . . 31)
= space = Hex 20
hh
= hours, (00. . . 23)
mm
= minutes, (00. . . 59)
ss
= seconds, (00. . . 59, or 60 while leap second)
fff
= milliseconds, (000. . . 999)
cc
= checksum*
<
CR
>
= Carriage Return = Hex 0D
*EXCLUSIVE-OR result of previous characters, displayed as HEX byte (2 ASCII characters 0. . . 9 or A. . . F)
Broadcast PATEK PHILIPPE MSG
Command:
BA, OA
Starts the Patek Philippe broadcast. BA = COM1. OA = COM2.
Response: T:yy:mm:dd:dw:hh:mm:ss
<
CR
><
LF
>
Where:
T
= on time mark, Hex 54
yy
= year
mm
= month
dd
= day of month
dw
= day of week
hh
= hour
mm
= minute
ss
= second
<
CR
>
= Carriage Return = Hex 0D
<
LF
>
= Line Feed = Hex 0A
Broadcast Mode: KISSIMMEE MSG
Command:
1,nTB
Starts the Kissimmee (Telegyr 5700) broadcast from the COM port that received the request.
Format:
n = time format: 0 = UTC, 1 = local
Response: ddd:hh:mm:ssQ
<
CR
><
LF
>
Where:
Q
= quality indicator (with indicators shown below)
space = Hex 20, locked, maximum accuracy
.
= Hex 2E, Error
<
1
µ
s
*
= Hex 2A, Error
<
10
µ
s
#
= Hex 23, Error
<
100
µ
s
?
= Hex 3F, Error
>
100
µ
s
<
CR
>
= Carriage Return = Hex 0D
<
LF
>