44
Utility Software
Auxiliary IRIG-B:
This is a completely independent instance of IRIG-B. Select
IRIG-B
as Mode
and go to IRIG-B tab to set up auxiliary time zone and IEEE C37.118.1 setting.
Polarity:
Pulses may be set to transition positively or negatively.
Single Trigger:
Specify the time and date, UTC or Local, for a pulse event.
Pulse Width:
From 10 ms (0.010 s) to 24 hours in 10 ms increments, depending on mode.
Pulse Delay:
The number of seconds after the top of the hour to delay the pulse in the Pulse per
Hour mode.
7.13.2
Auxiliary IRIG-B Mode
Select IRIG-B under
Mode
, and some of the other selections will normally change when you select
a different mode. Within this auxiliary IRIG-B mode, you will have the same setup variables as
with the standard IRIG-B outputs.
With any of these programmable pulses modes, make sure to select the Programmable Pulse
jumper assigned to the specific output port (1, 2, or 3). See Table 5.1.
Figure 7.12: Programmable Pulse Setup Screen