54
Utility Software
7.19
Setting to Factory Defaults
At some time it may be necessary to reset the clock to its original firmware configuration when it left
the factory. This is called “resetting to factory defaults” and requires disabling security. Resetting
the clock to factory defaults
clears memory
including any information that may cause problems with
its operation. To return the clock firmware configuration to factory defaults, follow the instructions
listed below. After resetting, you can use the Utility to save the default configuration to file.
1. Disable security (to level 0) on the clock using the utility software.
2. Cycle power on the clock: OFF, then ON.
3. Press the Setup key when you see the first message displayed on the LCD, and display message
should change to:
MODEL 120XX CLOCK
VERSION DDMMMYY
Then the display should change to read:
SET FACTORY DEFAULTS?
PRESS ENTER
4. Press the Enter key and the message should change to read:
ARE YOU SURE?
YES = UP NO = DOWN
5. Press the UP key to confirm. The display should cycle through the following messages.
LOADING DEFAULTS
DEFAULTS COMPLETE
6. The factory default settings are now restored.
7. Reset security on the clock if required.