Humidity:
•
“0” value disables the humidity control.
Radiation:
•
“0” value disables the radiation control on that particular light bank.
•
The minimum allowed value for radiation power control is “10”.
•
To control the radiation by
µ
mol setpoint, set the intensity to achieve, and also a
power (%) value different from “0” in the light bank(s) to be used. If the
µ
mol
setpoint is set to “0” and the power (%) is set to a value different from “0”, then the
radiation control is done only by power.
CO2:
•
“0” value disables the CO2 control.
•
After entering a CO2 setpoint, the CO2 read value will only be available after a
warmup period (normally 60s). Until then the shown value is “0”.
Irrigation:
•
To control irrigation, enable the corresponding option and enter the activation time
and period. If a soil moisture sensor is present, it is also possible to control the
irrigation based on a setpoint value.
Events:
•
Relay events are associated to free NO/NC relays that can be used to connect
external components. The connections are made though external connectors or
directly to the controller relays.