background image

4

1. 

INTRODUCTION

1.1 

Product description

VISIO MULTIFLOW is a multifunction display specifically designed to be connected to the ORION MULTIFLOW multi flowmeter.  
Up to 4 multi flowmeters, corresponding to 16 channels, can be connected.

2. 

INTENDED USE

This device is designed to work on agricultural machinery for spraying and crop spraying applications.

The machine is designed and built in compliance with EN ISO 14982:2009 standard (Electromagnetic compatibility - Forestry and farming

machines) harmonized with 2014/30/UE Directive.

3. 

CONTENT OF THE PACKAGE

The table below indicates the components that you will find in the VISIO MULTIFLOW package:

Legend:

1

  VISIO MULTIFLOW

2

  Fixing kit

4. 

PRECAUTIONS

• Do not aim water jets at the equipment.
• Do not use solvents or fuel to clean the case outer surface.
• Do not clean equipment with direct water jets.
• Comply with the specified power voltage (12 Vdc).
• In case of voltaic arc welding, remove connectors from VISIO MULTIFLOW and disconnect the power cables.
• Only use ARAG genuine spare parts and accessories.

5. 

INSTALLATION

5.1 

Risks and protections before assembly

All installation works must be done with battery disconnected, using suitable tools and any individual protection equipment deemed 

necessary.

5.2 

Positioning

1) Set mounting rail in cabin and fasten it with the relevant screws (

1

), in a position where VISIO 

MULTIFLOW can be easily seen and at hands' reach, but away from any moving organs.
2) Secure VISIO MULTIFLOW to rail and push down until locked in place.
3) Fasten wiring so that it does not interfere with any moving parts.

5.3 

Power supply and sensor connection

Sensors and power supply must be installed and connected by qualified personnel.  
VISIO MULTIFLOW must be exclusively connected to ARAG equipment.
WHEN ARC WELDING IS REQUIRED, MAKE SURE THAT EQUIPMENT POWER IS SWITCHED OFF; DISCONNECT POWER CABLES IF 
NEEDED.

ARAG is not liable for damage to the system, persons, animals or property caused by VISIO MULTIFLOW wrong or unsuitable 

assembly. Failure to observe the above instructions automatically voids the warranty.

Wire color  

(power cable)

Connection of

red

 positive

black

 negative

green

counting abort -  

ground connection

green

counting abort - 

conn12 VDC

Cable kit 

for VISIO 

MULTIFLOW 

to be ordered 

separately: COD. 

4670611.510

power supply

sensors

Summary of Contents for VISIO MULTIFLOW 4670611

Page 1: ...Software rel 1 2 x 4670611 INSTALLATION USE AND MAINTENANCE DISPLAY FOR MULTICHANNEL FLOWMETER...

Page 2: ...calibration 12 9 2 4 Automatic calibration 13 9 3 JOB SETTING 14 9 3 1 Number of rows 14 9 3 2 Inter row width 14 9 3 3 Application rate 15 9 4 OPTIONS 16 9 4 1 Language 16 9 5 UNITS OF MEASUREMENT 1...

Page 3: ...puts channels or rows up to 4 present in each multi flowmeter This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownershi...

Page 4: ...ATION 5 1 Risks and protections before assembly All installation works must be done with battery disconnected using suitable tools and any individual protection equipment deemed necessary 5 2 Position...

Page 5: ...Power cable 2 Speed sensor connection cables 3 ORION MULTIFLOW Flowmeters connection cables 4 ORION MULTIFLOW Flowmeters 5 Speed sensors and job status SUPERSEAL TE 4 POLE CONNECTOR Position Connectio...

Page 6: ...eral diagram par 5 4 Use ARAG sensors use of unsuitable sensors not provided by ARAG automatically voids the warranty ARAG is not liable for damage to the equipment persons or animals caused by failur...

Page 7: ...the equipment The Multiflow assembly direction must be correctly set since it allows the exact combination of the row on the machine with the symbol appearing on the display Setup menu Sensors Option...

Page 8: ...A Press for 2 seconds l 1 1 km ha 0 00 0000 0 0000 0 ACCESS TO SETUP MENU From the main page press keys at the same time for 2 seconds to open the Setup Menu Menu impostazioni Allarmi Sensori Opzioni...

Page 9: ...9 8 MENU STRUCTURE...

Page 10: ...igits B Press a few times to edit the highlighted digit C Press to save changes or D Press to quit the page without confirming changes 9 1 2 Speed alarms Set minimum and maximum speed thresholds for a...

Page 11: ...ough digits B Press a few times to edit the highlighted digit C Press to save changes or D Press to quit the page without confirming changes 9 1 4 Flowmeter status alarms Enable disable the alarm corr...

Page 12: ...f capacity with water 9 2 3 Manual calibration Manual calibration allows to enter the wheel constant value calculated with the suitable formula Kwheel distance traveled cm no of detection points x whe...

Page 13: ...er of pulses will increase during the path and the bottom area will indicate instant speed reading Stop the tractor at the end of the distance If a malfunction occurs the message Check sensor will be...

Page 14: ...ted digit C Press to save changes or D Press to quit the page without confirming changes Possibilty to connect up to 4 ORION MULTIFLOW flowmeters and able to read the data of 16 channels at the same t...

Page 15: ...et up Application rate The display will show the current value below the selected item Press OK to edit the application rate Application rate Min Value Max Value 0 0 1000 0 000 0 0 C D B A l ha 2 Set...

Page 16: ...surem Flowrate Volume Speed l min 1 Open instant rate unit of measurement setting menu Setup menu Options Units of measurem Flowrate The display will show the current value below the selected item Pre...

Page 17: ...surement setting menu Setup menu Options Units of measurem Length The display will show the current value below the selected item Press OK to select length unit of measurement 1 Select a unit through...

Page 18: ...of measurement 2 1 2 Application Rate l ha GPA GPK 1 Select a unit through 2 Press OK to save or ESC to quit without saving 9 5 7 Distance units of measurement Units of measurem Surface Distance km Ap...

Page 19: ...able disable the alarm tones Options Units of measurem Display contrast Alarm tones ON Open alarm tones menu Setup menu Options Alarm tones The display will show the current setting below the selected...

Page 20: ...OT 2 Distance Flowrate Speed 1 Set sector to the required value through 2 Press OK to save or ESC to quit without saving Carry out the same procedure for the other 2 values 9 10 ID DELETION This menu...

Page 21: ...to set VISIO MULTIFLOW again WARNING By loading the SETUP BIN file contained in the USB pen drive onto the VISIO MULTIFLOW all current settings will be lost 1 Select the desired control through 2 Pre...

Page 22: ...alue Symbol indicates that totalizer exceed maximum value that can be displayed Totalizers have a floating point and show a maximum of 4 digits Two decimals are shown up to 999 99 One decimal is shown...

Page 23: ...tral area shows the detected average value for all the rows The arrow is displayed below every rectangle 1 55l min 43 6 km h Press or two seconds to disable the reading of the data for the row indicat...

Page 24: ...wer voltage 1 Open display test menu Setup menu Test Display Press OK to perform the test All pixels on display are turned on Press ESC to go back to previous page 10 4 KEYS TEST Keys test checks the...

Page 25: ...Multiflow 3 Multiflow 4 Test Sensors Display Keys Open sensors test menu Setup menu Test Sensors Press OK to perform the test Speed sensor 382 8 Hz Sensors External enable Multiflow The display will...

Page 26: ...to quit Status Multiflow 1 Power voltage Temperatura For each multi flowmeter installed the following information may be checked Status Power supply voltage Temperature Flowmeter 1 Flowmeter 2 Flowme...

Page 27: ...ault Contact the nearest Assistance Center VISIO MULTIFLOW fault 12 TECHNICAL DATA Description VISIO MULTIFLOW Display Graphic LCD 128 x 64 pixels back lighting Power supply voltage 9 16 Vdc Protectio...

Page 28: ...vered by the guarantee damage caused by transport scratches dents and similar damage due to incorrect installation or to faults originating from insufficient or inadequate characteristics of the elect...

Page 29: ...Notes 29...

Page 30: ...Notes 30...

Page 31: ...31...

Page 32: ...39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time Alway...

Reviews: