background image

12

9.2 

SENSORS

9.2.1 

Speed sensor

Setup menu

Sensors

Options

Alarms

1) Open Sensors menu (Setup menu > Sensors ).

Multiflow orient.

Sensors

Speed sensor

1) Access the Speed sensor menu (Settings menu > Sensors > Speed sensor) to 

calibrate the sensor.

9.2.2 

Speed sensor calibration

VISIO MULTIFLOW calculates the information concerning the speed thanks to pulses received by the sensor installed on the wheel.
To perform speed sensor calibration, proceed as follows:
-Measure a straight path at least 100 m (300 feet) long.
The longer the distance traveled, the more accurate the wheel constant calculation.
- Take measurements with tyres at the operating pressure.
This test must be performed on medium-hard terrain; for application to very soft or very hard terrain, rolling diameter may vary, leading to inaccurate output 
calculation; when this is the case, repeat the procedure.
During the test, cover the distance with the tank filled up to half capacity with water.

9.2.3 

Manual calibration

Manual calibration allows to enter the wheel constant value calculated with the suitable formula:

Kwheel =

distance traveled (cm)

no. of detection points x wheel rpm

<distance traveled>

 

distance expressed in cm covered by the wheel along measurement travel;

<no. of measurement points>

 

number of measurement points (e.g., magnets, bolts, etc.), mounted on wheel;

<no. of wheel revolutions>

 

number of wheel revolutions required to travel measurement distance.

The wheel constant can be calculated with a good approximation by detecting the distance traveled by the wheel with the speed sensor.

Speed sensor

Auto calibration

Man. calibration

60.0 cm/pls

1) Open manual calibration menu (Setup menu > Sensors > Speed sensor > Man. 

Calibration).

C

B

D

A

Speed sensor

Min Value
Max Value

0.10

200.00

60.00

0

cm/pls

Cover the requested distance. Stop the tractor at the end of the distance and calculate 

wheel constant

 

(Kwheel)

.

2) Set wheel constant value:

A) Press to move through digits;

B) Press a few times to edit the highlighted digit;

C) Press to save changes, or; 

D) Press to quit the page without confirming changes.

Summary of Contents for VISIO MULTIFLOW 4670611

Page 1: ...Software rel 1 2 x 4670611 INSTALLATION USE AND MAINTENANCE DISPLAY FOR MULTICHANNEL FLOWMETER...

Page 2: ...calibration 12 9 2 4 Automatic calibration 13 9 3 JOB SETTING 14 9 3 1 Number of rows 14 9 3 2 Inter row width 14 9 3 3 Application rate 15 9 4 OPTIONS 16 9 4 1 Language 16 9 5 UNITS OF MEASUREMENT 1...

Page 3: ...puts channels or rows up to 4 present in each multi flowmeter This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownershi...

Page 4: ...ATION 5 1 Risks and protections before assembly All installation works must be done with battery disconnected using suitable tools and any individual protection equipment deemed necessary 5 2 Position...

Page 5: ...Power cable 2 Speed sensor connection cables 3 ORION MULTIFLOW Flowmeters connection cables 4 ORION MULTIFLOW Flowmeters 5 Speed sensors and job status SUPERSEAL TE 4 POLE CONNECTOR Position Connectio...

Page 6: ...eral diagram par 5 4 Use ARAG sensors use of unsuitable sensors not provided by ARAG automatically voids the warranty ARAG is not liable for damage to the equipment persons or animals caused by failur...

Page 7: ...the equipment The Multiflow assembly direction must be correctly set since it allows the exact combination of the row on the machine with the symbol appearing on the display Setup menu Sensors Option...

Page 8: ...A Press for 2 seconds l 1 1 km ha 0 00 0000 0 0000 0 ACCESS TO SETUP MENU From the main page press keys at the same time for 2 seconds to open the Setup Menu Menu impostazioni Allarmi Sensori Opzioni...

Page 9: ...9 8 MENU STRUCTURE...

Page 10: ...igits B Press a few times to edit the highlighted digit C Press to save changes or D Press to quit the page without confirming changes 9 1 2 Speed alarms Set minimum and maximum speed thresholds for a...

Page 11: ...ough digits B Press a few times to edit the highlighted digit C Press to save changes or D Press to quit the page without confirming changes 9 1 4 Flowmeter status alarms Enable disable the alarm corr...

Page 12: ...f capacity with water 9 2 3 Manual calibration Manual calibration allows to enter the wheel constant value calculated with the suitable formula Kwheel distance traveled cm no of detection points x whe...

Page 13: ...er of pulses will increase during the path and the bottom area will indicate instant speed reading Stop the tractor at the end of the distance If a malfunction occurs the message Check sensor will be...

Page 14: ...ted digit C Press to save changes or D Press to quit the page without confirming changes Possibilty to connect up to 4 ORION MULTIFLOW flowmeters and able to read the data of 16 channels at the same t...

Page 15: ...et up Application rate The display will show the current value below the selected item Press OK to edit the application rate Application rate Min Value Max Value 0 0 1000 0 000 0 0 C D B A l ha 2 Set...

Page 16: ...surem Flowrate Volume Speed l min 1 Open instant rate unit of measurement setting menu Setup menu Options Units of measurem Flowrate The display will show the current value below the selected item Pre...

Page 17: ...surement setting menu Setup menu Options Units of measurem Length The display will show the current value below the selected item Press OK to select length unit of measurement 1 Select a unit through...

Page 18: ...of measurement 2 1 2 Application Rate l ha GPA GPK 1 Select a unit through 2 Press OK to save or ESC to quit without saving 9 5 7 Distance units of measurement Units of measurem Surface Distance km Ap...

Page 19: ...able disable the alarm tones Options Units of measurem Display contrast Alarm tones ON Open alarm tones menu Setup menu Options Alarm tones The display will show the current setting below the selected...

Page 20: ...OT 2 Distance Flowrate Speed 1 Set sector to the required value through 2 Press OK to save or ESC to quit without saving Carry out the same procedure for the other 2 values 9 10 ID DELETION This menu...

Page 21: ...to set VISIO MULTIFLOW again WARNING By loading the SETUP BIN file contained in the USB pen drive onto the VISIO MULTIFLOW all current settings will be lost 1 Select the desired control through 2 Pre...

Page 22: ...alue Symbol indicates that totalizer exceed maximum value that can be displayed Totalizers have a floating point and show a maximum of 4 digits Two decimals are shown up to 999 99 One decimal is shown...

Page 23: ...tral area shows the detected average value for all the rows The arrow is displayed below every rectangle 1 55l min 43 6 km h Press or two seconds to disable the reading of the data for the row indicat...

Page 24: ...wer voltage 1 Open display test menu Setup menu Test Display Press OK to perform the test All pixels on display are turned on Press ESC to go back to previous page 10 4 KEYS TEST Keys test checks the...

Page 25: ...Multiflow 3 Multiflow 4 Test Sensors Display Keys Open sensors test menu Setup menu Test Sensors Press OK to perform the test Speed sensor 382 8 Hz Sensors External enable Multiflow The display will...

Page 26: ...to quit Status Multiflow 1 Power voltage Temperatura For each multi flowmeter installed the following information may be checked Status Power supply voltage Temperature Flowmeter 1 Flowmeter 2 Flowme...

Page 27: ...ault Contact the nearest Assistance Center VISIO MULTIFLOW fault 12 TECHNICAL DATA Description VISIO MULTIFLOW Display Graphic LCD 128 x 64 pixels back lighting Power supply voltage 9 16 Vdc Protectio...

Page 28: ...vered by the guarantee damage caused by transport scratches dents and similar damage due to incorrect installation or to faults originating from insufficient or inadequate characteristics of the elect...

Page 29: ...Notes 29...

Page 30: ...Notes 30...

Page 31: ...31...

Page 32: ...39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time Alway...

Reviews: