background image

26

10.5.2 

External activation test

Sensors

Speed sensor

External enable

...

Multiflow

The display shows the current external activation been in use.

10.5.3 

Multi flowmeters test

This menu allows to get information about each multi flowmeter and the corresponding flowmeters.

Sensors

Speed sensor
External enable

Multiflow

...

Open Multi flowmeters test menu (Setup menu > Test > Sensors > Multi flowmeters).
Press 

OK

 to perform the test.

Installation

Multiflow

Multiflow 1
Multiflow 2

1) Select through

 

 

key.

2) Press 

ESC

 to quit.

Status

Multiflow 1

Power voltage
Temperatura

...

For each multi flowmeter installed, the following information may be checked: 

 

-

Status;

 

-

Power supply voltage;

 

-

Temperature;

 

-

Flowmeter 1;

 

-

Flowmeter 2;

 

-

Flowmeter 3;

 

-

Flowmeter 4;

Use 

 to scroll the information to be displayed.

Flowrate

Flowmeter 1

Status code
Error code

...

For each row of the flowmeter (Flowmeter 1,2,3,4) you can also check: 

Flowrate 

Status

code

 and 

Error code

.

Use 

 to scroll the information to be displayed.

Status code

Error code

0 measurement disabled

1

wrong calibration

1

measurement enabled,  
liquid not flowing

2

liquid not detected

2 measurement enabled, liquid flowing

4

wrong power supply

3 measurement suspended / device busy

8

overtemperature

Summary of Contents for VISIO MULTIFLOW 4670611

Page 1: ...Software rel 1 2 x 4670611 INSTALLATION USE AND MAINTENANCE DISPLAY FOR MULTICHANNEL FLOWMETER...

Page 2: ...calibration 12 9 2 4 Automatic calibration 13 9 3 JOB SETTING 14 9 3 1 Number of rows 14 9 3 2 Inter row width 14 9 3 3 Application rate 15 9 4 OPTIONS 16 9 4 1 Language 16 9 5 UNITS OF MEASUREMENT 1...

Page 3: ...puts channels or rows up to 4 present in each multi flowmeter This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownershi...

Page 4: ...ATION 5 1 Risks and protections before assembly All installation works must be done with battery disconnected using suitable tools and any individual protection equipment deemed necessary 5 2 Position...

Page 5: ...Power cable 2 Speed sensor connection cables 3 ORION MULTIFLOW Flowmeters connection cables 4 ORION MULTIFLOW Flowmeters 5 Speed sensors and job status SUPERSEAL TE 4 POLE CONNECTOR Position Connectio...

Page 6: ...eral diagram par 5 4 Use ARAG sensors use of unsuitable sensors not provided by ARAG automatically voids the warranty ARAG is not liable for damage to the equipment persons or animals caused by failur...

Page 7: ...the equipment The Multiflow assembly direction must be correctly set since it allows the exact combination of the row on the machine with the symbol appearing on the display Setup menu Sensors Option...

Page 8: ...A Press for 2 seconds l 1 1 km ha 0 00 0000 0 0000 0 ACCESS TO SETUP MENU From the main page press keys at the same time for 2 seconds to open the Setup Menu Menu impostazioni Allarmi Sensori Opzioni...

Page 9: ...9 8 MENU STRUCTURE...

Page 10: ...igits B Press a few times to edit the highlighted digit C Press to save changes or D Press to quit the page without confirming changes 9 1 2 Speed alarms Set minimum and maximum speed thresholds for a...

Page 11: ...ough digits B Press a few times to edit the highlighted digit C Press to save changes or D Press to quit the page without confirming changes 9 1 4 Flowmeter status alarms Enable disable the alarm corr...

Page 12: ...f capacity with water 9 2 3 Manual calibration Manual calibration allows to enter the wheel constant value calculated with the suitable formula Kwheel distance traveled cm no of detection points x whe...

Page 13: ...er of pulses will increase during the path and the bottom area will indicate instant speed reading Stop the tractor at the end of the distance If a malfunction occurs the message Check sensor will be...

Page 14: ...ted digit C Press to save changes or D Press to quit the page without confirming changes Possibilty to connect up to 4 ORION MULTIFLOW flowmeters and able to read the data of 16 channels at the same t...

Page 15: ...et up Application rate The display will show the current value below the selected item Press OK to edit the application rate Application rate Min Value Max Value 0 0 1000 0 000 0 0 C D B A l ha 2 Set...

Page 16: ...surem Flowrate Volume Speed l min 1 Open instant rate unit of measurement setting menu Setup menu Options Units of measurem Flowrate The display will show the current value below the selected item Pre...

Page 17: ...surement setting menu Setup menu Options Units of measurem Length The display will show the current value below the selected item Press OK to select length unit of measurement 1 Select a unit through...

Page 18: ...of measurement 2 1 2 Application Rate l ha GPA GPK 1 Select a unit through 2 Press OK to save or ESC to quit without saving 9 5 7 Distance units of measurement Units of measurem Surface Distance km Ap...

Page 19: ...able disable the alarm tones Options Units of measurem Display contrast Alarm tones ON Open alarm tones menu Setup menu Options Alarm tones The display will show the current setting below the selected...

Page 20: ...OT 2 Distance Flowrate Speed 1 Set sector to the required value through 2 Press OK to save or ESC to quit without saving Carry out the same procedure for the other 2 values 9 10 ID DELETION This menu...

Page 21: ...to set VISIO MULTIFLOW again WARNING By loading the SETUP BIN file contained in the USB pen drive onto the VISIO MULTIFLOW all current settings will be lost 1 Select the desired control through 2 Pre...

Page 22: ...alue Symbol indicates that totalizer exceed maximum value that can be displayed Totalizers have a floating point and show a maximum of 4 digits Two decimals are shown up to 999 99 One decimal is shown...

Page 23: ...tral area shows the detected average value for all the rows The arrow is displayed below every rectangle 1 55l min 43 6 km h Press or two seconds to disable the reading of the data for the row indicat...

Page 24: ...wer voltage 1 Open display test menu Setup menu Test Display Press OK to perform the test All pixels on display are turned on Press ESC to go back to previous page 10 4 KEYS TEST Keys test checks the...

Page 25: ...Multiflow 3 Multiflow 4 Test Sensors Display Keys Open sensors test menu Setup menu Test Sensors Press OK to perform the test Speed sensor 382 8 Hz Sensors External enable Multiflow The display will...

Page 26: ...to quit Status Multiflow 1 Power voltage Temperatura For each multi flowmeter installed the following information may be checked Status Power supply voltage Temperature Flowmeter 1 Flowmeter 2 Flowme...

Page 27: ...ault Contact the nearest Assistance Center VISIO MULTIFLOW fault 12 TECHNICAL DATA Description VISIO MULTIFLOW Display Graphic LCD 128 x 64 pixels back lighting Power supply voltage 9 16 Vdc Protectio...

Page 28: ...vered by the guarantee damage caused by transport scratches dents and similar damage due to incorrect installation or to faults originating from insufficient or inadequate characteristics of the elect...

Page 29: ...Notes 29...

Page 30: ...Notes 30...

Page 31: ...31...

Page 32: ...39 0522 622011 Fax 39 0522 628944 www aragnet com info aragnet com Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time Alway...

Reviews: