13
9.2.4
Automatic calibration
Calculate and save the wheel constant according to the procedure below:
Speed sensor
Man. calibration
Auto calibration
...
1) Open automatic calibration menu (Setup menu > Sensors > Speed sensor > Auto
Calibration).
Go! 100m
pls
Constant calc.
¬
¬
0
As soon as menu is open, the equipment is ready to start measuring with no
further controls being required.
6.0 km/h
pls
Constant calc.
¬
¬
30
Cover the requested distance: the number of pulses will increase during the path and the
bottom area will indicate instant speed reading.
Stop the tractor at the end of the distance.
If a malfunction occurs, the message
Check sensor!
will be shown
in the top part of the display
.
Speed sensor
Man. calibration
Auto calibration
65.2 cm/pl
Press
OK
to stop the counting. The display will go back to the previous menu and will
show the acquired value.
In case of measurement errors, or if it is necessary to stop the calibration, press
ESC
for 2 seconds to quit the calibration procedure without saving.
In this case, the value will be the one previously measured, or the default value.