PRELIMINARY SETUP FOR USE - SETUP MENU
9.1
ALARMS
9.1.1
Flowrate alarms
Set minimum and maximum flowrate thresholds for alarm message.
Minimum and maximum rate alarms are set in the same way.
Alarms
Min flowrate
OFF
Max flowrate
1) Open Alarm menu (Setup menu > Alarms).
The display will show the current setting below the selected item.
Press
OK
to edit the selected menu item.
Min flowrate
Min Value
Max Value
0.1
1000.0
OFF
o
2) To activate the alarm, press
and
at the same time until message
OFF
goes
off and rate alarm value is displayed instead.
Carry out the same procedure to disable alarm again.
C
B
D
A
Min flowrate
Min Value
Max Value
0.1
1000.0
0040.0
0
l/min
o
3) Set alarm value:
A) Press to move through digits;
B) Press a few times to edit the highlighted digit;
C) Press to save changes, or;
D) Press to quit the page without confirming changes.
9.1.2
Speed alarms
Set minimum and maximum speed thresholds for alarm message.
Minimum and maximum speed alarms are set in the same way.
Alarms
Min speed
OFF
Max speed
1) Open Alarm menu (Setup menu > Alarms).
The display will show the current setting below the selected item.
Press
OK
to edit the selected menu item.
Min speed
Min Value
Max Value
1.0
100.0
OFF
o
2) To activate the alarm, press
and
key at the same time until message
OFF
goes off and speed alarm value is displayed instead.
Carry out the same procedure to disable alarm again.
C
B
D
A
Min speed
Min Value
Max Value
0.1
1000.0
01.0
0
km/h
o
3) Set alarm value:
A) Press to move through digits;
B) Press a few times to edit the highlighted digit;
C) Press to save changes, or;
D) Press to quit the page without confirming changes.