39
• Output values
Data
Min.
Max.
UoM
Description
Notes
Volume applied
0.0
99999,9
US: GPA
Quantity of sprayed fluid for unit of
surface
Shown on the first line of the display, during treatment
0.00
99999,99
US TURF: GPK
Speed
0.0
199,9
US - US TURF: MPH
Vehicle driving speed
--
Pressure
0
9999
US: PSI
Output pressure
Present only if YES has been set in the advanced
menu "Pressure calculation"
Flow
0.0
999,9
US - US TURF: GPM
Fluid sprayed per time unit
Fluid actually sprayed by the nozzles
Area
0.000
999999
US: acres
Sprayed surface
Floating point
The totalizer increases when the main switch is ON
0.000
999999 US TURF: 1000 square ft
Sprayed qty
0
999999
US - US TURF: gal
Sprayed fluid
The totalizer increases when the main switch is ON
Tank level
0
5500
US - US TURF: gal
Remaining fluid in the tank
Floating point
The totalizer decreases when the main switch is ON
Time
00:00
10000
EU - US - US TURF: h
Treatment time
Floating point
The totalizer increases when the main switch is ON
From 00:01 to 99:59 the format is hh:mm
Distance
0.000
99999
US - US TURF: miles
Traveled distance
Floating point
The totalizer increases when the main switch is OFF
16.1
Computer technical data
Description
Display
Alphanumeric LCD
2 lines x 16 characters, backlit
Power supply voltage
11 ÷ 14 Vdc
Consumption (valves excluded)
150 mA
Operating temperature
+32°F ÷ +140 °F
0°C ÷ 60 °C
Digital inputs
for open collector sensors: max 2000 imp/s
Weight
28.22 oz - Bravo without hydraulic controls
40.21 oz - Bravo with hydraulic controls
(without harness)
Protection against polarity inversion
•
Protection against short-circuit
•
TECHNICAL DATA