VP5000-DC/DC60, VP5000-DC/DC200-HL
Operation
Last edited 2019-02-08
by Sonja Scheunert
Filename
VP5000_DCDC60_200-HL_installation_manual_v1-4en.docx
152 / 173
•
If you need assistance, contact ARADEX customer service. Depending on the effort involved, a
visit by a customer service representative may incur costs, for example, if the expert is on site
for several days. The manufacturer and customer service address is found on the back of the
cover sheet.
7.7.2
Checklist for malfunctions
Most faults can be rectified with the help of the following checklist.
Possible causes of malfunctions:
For further information see
chapter
VECTOPOWER does not function correctly
Are the power data, current and voltage limits adhered to?
3.3.1, 3.3.2, 3.3.3, 3.9, 3.10,
3.11
Are the power connections correctly established: Are [DC+/-],
[/-], and, if necessary, [BR+/-] reversed?
Is the polarity of the power connections correct?
For example, is [DC+] connected to [DC+]?
Check the EMC cable glands:
Are the EMC cable glands installed correctly?
Are the mating connectors of the logical connections tight?
Are the crimp contacts and mating connectors installed
correctly?
6.3.8, 6.3.9
6.3.5, 6.3.6, 6.3.7
Check the cable lugs of the power connections:
Are the cable lugs installed correctly?
Are the bolts tightened with the correct torque and secured with
a pair of Nord-Lock wedge lock washers?
Is the cable shield of [ST1] correctly grounded?
What messages are displayed in VEConfig?
VEConfig operating manual
VE operating manual
Are the versions of VE, the parameter set, VEConfig, and the
software compatible in the higher-level controller?
VEConfig operating manual
VE operating manual
Are the parameters correctly set?
VEConfig operating manual
VE operating manual
Optional only for VECTOPOWER VP5000-DC/DC60: Is [ST4]
correctly connected to [] for voltage measurement? If
available, has the external precharging circuit been taken into
account?
VECTOPOWER does not deliver full power or switch itself off
Are the parameters correctly set?
VEConfig operating manual
VE operating manual
Does the cooling work?
Are the operating conditions observed: e.g., height above sea
level, temperature range?
Table 54: Checklist of malfunctions