VP5000-DC/DC60, VP5000-DC/DC200-HL
Product description
Last edited 2019-02-08
by Sonja Scheunert
Filename
VP5000_DCDC60_200-HL_installation_manual_v1-4en.docx
31 / 173
[ST2]: Digital output 5 and 6
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
Maximum output voltage
24 V (depending on the supply
voltage for the logical connections)
-/-
Maximum current
(connected to ground)
1.7 A
-/-
Impedance (connected to
ground)
220 m
Ω
-/-
Table 13: Electrical data - digital output 5 and 6 to [ST2]
3.3.6
Interfaces
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
Communication bus
VECTOBUS, CAN
VECTOBUS, CAN
Number of NTC (PTC)
inputs
3
3
Number of PT100 inputs
2
2
Analog inputs
2
2
Logic inputs
4
2
Logic outputs (0.2 A each)
2
2
Table 14: Interfaces
3.3.7
General data and environmental data
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
Weight
33 kg / 72.8 lb
75 kg / 165.3 lb
Ambient temperature
-25 °C to 45 °C / -13 °F to 113 °F
Maximum ambient
temperature with derating
75 °C / 167 °F
Air humidity according to
IEC 60068-2-35
Max. 90%, non-condensing
Sound pressure
Not defined
Operating range, altitude
above sea level Overvoltage
category / Pollution degree
Operating range: 0 – 2000
m / 0 – 6560
ft
Overvoltage category: III
Pollution degree: II
Operating range, altitude
above sea level/
Overvoltage category /
Pollution degree
Operating range: 0 – 4000
m / 0 – 13123
ft
Overvoltage category: I
Pollution degree: II
IP protection class of the
housing
VP5000-DC/DC200-HL with hardware version 1.0 have IP20.
VP5000-DC/DC200-HL with hardware version 1.1 and higher have IP65.
VP5000-DC/DC60 with hardware version 1.0 and higher have IP65.