Procedure:
Figure 85: Example of double nipple from Pflitsch,
blueglobe TRI type
Screw the EMC cable gland into the
housing:
(Here shown using the example of an EMC
cable gland from Pflitsch, blueglobe TRI type.)
1.
Screw the double nipple (2) with the
thread (a) into the respective opening of
the housing.
2.
Tighten the double nipple with the torque
specified by the manufacturer.
3.
Repeat the procedure until all double
nipples (2) are screwed into the device.
Figure 86: Example of a screwed-in double nipple
with spring (Pflitsch, blueglobe TRI type)
4.
Insert the spring (1) into the double nipple
(2) of the EMC cable gland.
5.
Repeat the procedure until all springs (1)
are inserted into all double nipples (2).