5.15
INST
ALLA
TION
c. Suspend the Intake Hose in the flow by engaging the Intake Hose
Anchor with the Intake Hose Support.
d. Run the Intake Hose along its designated path up to the Sampler
Intake.
e. Attach the upper end of the Intake Hose to the Sample Intake:
S50 Sampler
Note: Strain relief for the upper end of the Intake Hose is not provided
with the S50 and in applications where this is judged to be necessary;
a suitable Strain Relief Bracket should be installed.
In many applications where there is just a short lift and the flow is not
vigorous, strain relief of the upper end of the Intake Hose may not be
necessary.
If strain relief is required for the upper end of the Intake Hose,
proceed as follows:
a. Attach a second Intake Hose Anchor to the upper end of the
Intake Hose at a point such that, when it engages with the Strain
Relief Bracket, it suspends in its intended manner.
b. Suspend the Intake Hose by engaging the Intake Hose Anchor
with the Strain Relief Bracket.
c. Cut the Intake Hose to length so that the free end is able to
engage with the Intake Pipe on the Sampler Module (Allow about
20mm of hose to engage with the Intake Pipe).
d. Place the Intake Hose Clip over the free end of the Intake Hose
and soften the end of the hose by the application of heat using a
hot air gun.
e. Push the hose onto the Intake Pipe so that approximately 20mm
is engaged and secure in place by tightening the Intake Hose Clip,
using pliers.
Note: If strain relief is not required for the upper end of the Intake
Hose, proceed from c) above.
S100 and S200 Samplers
Attach the Strain Relief Bracket supplied to the side of the Sampler
Module using the 2 M4 screws/washers.