122
Note1
Note2
Note3
Note4
Voltage Range = Low
310XAC=0.000-9.20
320XAC=0.000-18.40
340XAC=0.00-36.80
360XAC=0.00-55.20
Voltage Range = High
310XAC=0.000-4.60
320XAC=0.000-9.20
340XAC=0.00-18.40
360XAC=0.00-27.60
Voltage Range = Low
310XAC=0.000-4.80
320XAC=0.000-9.60
340XAC=0.00-19.20
360XAC=0.00-28.80
Voltage Range = High
310XAC=0.000-2.40
320XAC=0.000-4.80
340XAC=0.00-9.60
360XAC=0.00-14.40
310XAC=0.0-1000
320XAC=0.0-2000
340XAC=0-4000
360XAC=0-6000
Voltage Range = Low
310XAC=0.0-36.8
320XAC=0.0-73.6
340XAC=0.0-147.2
360XAC=0.0-220.8
Voltage Range = High
310XAC=0.0-18.4
320XAC=0.0-36.8
340XAC=0.0-73.6
360XAC=0.0-110.4
9.4.5 System Commands and Companion Queries
These commands are used to modify the system parameters for the instrument.
These commands require a parameter value to be included with the command.
The companion query command will read the parameter using the same value
that is used for setting the parameter.
Command
Description
AC Program Mode
AC Manual
Mode
DC Program Mode
DC Manual
Mode
Unit
AR X
AUTO RUN X
X=0~1,0=PROGRAM,1=MANUAL
AR?
AUTO RUN?
0~1
OM X
OUT MODE X
X=0~1,0=AC,1=DC
OM?
OUT MODE?
0~1
SS X
SINGLE STEP
X
X=0~1, 0=OFF,1=ON
X=0~1,0=OFF,1=ON
SS?
SINGLE
STEP?
0~1
0~1
ALARM X
ALARM X
X=0~9, 0=OFF,9=high
ALARM?
ALARM?
0~9
CONTRAST
X
CONTRAST X
X=1~9, 9=high
CONTRAST?
CONTRAST?
1~9
PUP X
POWER UP X
X=0-2,0=OFF,1=ON,2=LAST
PUP?
POWER UP?
0-2
LC XXXX
LOOP CYCLE
XXXX
XXXX=0~9999 ,0=Cont,1=OFF
XXXX=0~9999 ,0=Cont,1=OFF
LC?
LOOP
CYCLE?
0-9999
0-9999
VHI XXXX
VOLT HI XXXX
XXXX=5.0~300.0
XXXX=5.0~420.0
V
VHI?
VOLT HI?
5.0~300.0
5.0~420.0
V
VLO XXXX
VOLT LO
XXXX
XXXX=5.0~300.0
XXXX=5.0~420.0
V
VLO?
VOLT LO?
5.0~300.0
5.0~420.0
V
FHI XXXX
FREQ HI
XXXX
XXXX=40.0~1000
Hz
Summary of Contents for 00310XAC
Page 16: ...10 310XAC 320XAC...
Page 24: ...18 Accuracy L 0 1 Hz 0 0 500 Hz H 0 2 Hz 501 1000 Hz...
Page 26: ...20 A...
Page 36: ...30...
Page 101: ...95 move back to the test screen...
Page 108: ...102...
Page 127: ...121 CONNECT CONNECT 0 1 0 1...
Page 130: ...124 Register...
Page 138: ...132...