119
of the parameter requires that the unit not be included with the value, only the
numeric value should be included with the command. Also, when the query
commands are sent, the response will not include the unit characters.
Command
Description
AC Program Mode
AC Manual
Mode
DC Program
Mode
DC Manual
Mode
Unit
NAME XXXX
MEMORY NAME
XXXX
XXXX=1~10 BYTES
NAME?
MEMORY NAME?
SAG XXXX
START ANGLE
XXXX
XXXX=0-359
°
SAG?
START ANGLE?
0-359
°
EAG XXXX
END ANGLE XXXX
XXXX=0-359
°
EAG?
END ANGLE?
0-359
°
MC XXXX
MEMORY CYCLE
XXXX
XXXX=0~9999,
0=Continue, 1=OFF
XXXX=0~9999,
0=Continue, 1=OFF
MC?
MEMORY CYCLE?
0-9999
0-9999
MEMORY X
MEMORY X
X=1-50
MEMORY?
MEMORY?
1-50
STEP X
STEP X
X=1-9
X=1-5
STEP?
STEP?
1-9
1-5
VOLT XXX.X
VOLTAGE XXX.X
XXXX=0.0~300.0
XXXX=5.0~420.0 or 5.0~210.0
V
VOLT?
VOLTAGE?
0.0~300.0
5.0~420.0 or 5.0~210.0
V
RANG X
RANG X
X=0-1, 0=HIGH,1=AUTO
X=0-1, 0=HIGH,1=LOW
RANG?
RANG?
0-1
FREQ XXXX
FREQUNCY XXXX
XXXX=40.0~1000
Hz
FREQ?
FREQUNCY?
40.0~1000
Hz
SD X
TRANSIENT X
X=0~1, 0=OFF,1=ON
SD?
TRANSIENT?
0~1
SDVOLT XXXX
TRANSIENT-VOLT
XXXX
XXXX=0.0~300.0
V
SDVOLT?
TRANSIENT-
VOLT?
0.0~300.0
V
SDLT XX.X
TRANSIENT-SITE
XX.X
XX.X=0.0~25.0
ms
SDLT?
TRANSIENT-SITE?
0.0~25.0
ms
SDHT XX.X
TRANSIENT-TIME
XX.X
XX.X=0.0~25.0
ms
SDHT?
TRANSIENT-
TIME?
0.0~25.0
ms
SDCT XXXX
TRANSIENT-
CYCLE XXXX
X=0~9999, 0=CONT,1=OFF
SDCT?
TRANSIENT-
CYCLE?
0~9999
RAMPUP XXXX
RAMP UP TIME
XXXX
XXX.X=0.1~999.9
XXX.X=0.1~999.9
s
RAMPUP?
RAMP UP TIME?
0.1~999.9
0.1~999.9
s
TUNIT X
TIME UNIT X
X=0-
2,0=Second,1=Minute,2=
Hour
X=0-
2,0=Second,1=Minute
,2=Hour
TUNIT?
TIME UNIT?
0-2
0-2
Summary of Contents for 00310XAC
Page 16: ...10 310XAC 320XAC...
Page 24: ...18 Accuracy L 0 1 Hz 0 0 500 Hz H 0 2 Hz 501 1000 Hz...
Page 26: ...20 A...
Page 36: ...30...
Page 101: ...95 move back to the test screen...
Page 108: ...102...
Page 127: ...121 CONNECT CONNECT 0 1 0 1...
Page 130: ...124 Register...
Page 138: ...132...