HI Power Supply User Manual
Technical Sales / Customer Service:
+1-818-338-
7788 • Email:
31328 Via Colinas Suite 102 • Westlake Village, CA 91362 USA •
10 / 31
Table 8
When using the signal 0-10V, please apply a voltage of 0V to 10V between pin 13 (0-10V) and pin 14.
Table 9 shows the corresponding output current when using this signal.
Table 9
Notes:
4.
Please note that 0-10V and 0-5V cannot be used at the same time
5.
If the user will use 0-10V, then 0-5V should be in a floating state
6.
If the user will use 0-5V, then 0-10V should be in a floating state
2.5 Isolated Output Enable
Provide input signal to enable output. Pin 9 is used as the enable signal of the module.
This pin is internally connected to the LED side of the optocoupler.
An external 1kohms pull-up resistor is required.
The pull-up resistor is connected to the 5V power supply.
The maximum pull-up resistor voltage is 5V, and the maximum sink current is 5mA.
When the start-up Pulse signal is greater than 70mS, the module starts.
Turn off the module and then start the Pulse signal again and it must be greater than 70mS The default
pin configuration is:
• Optocoupler LED On = Output is Enabled.
• Optocoupler LED Off = Output is Disabled.
0~5V
Corresponding Output Current
1V
20% Nominal Output Current
2.5V
50% Nominal Output Current
3V
60% Nominal Output Current
4V
80% Nominal Output Current
5V
100% Nominal Output Current
0~10V
Corresponding Output Current
1V
10% Nominal Output Current
2V
20% Nominal Output Current
3V
30% Nominal Output Current
4V
40% Nominal Output Current
5V
50% Nominal Output Current
7.5V
75% Nominal Output Current
8.6V
86% Nominal Output Current
10V
100% Nominal Output Current