HI Power Supply User Manual
Technical Sales / Customer Service:
+1-818-338-
7788 • Email:
31328 Via Colinas Suite 102 • Westlake Village, CA 91362 USA •
8 / 31
PIN 21: Used as the Current monitoring signal of the module. It reports Detect the output current by
scaling the voltage in the range of 0 to 5V.
PIN 22: Used as the reference signal ground for the current monitoring signal (0~5V) of the module.
PIN 23: Used as the Current monitoring signal of the module. It reports Detect the output current by
scaling the voltage in the range of 0 to 10V.
PIN 24: Used as the reference signal ground for the current monitoring signal (0~10V) of the module.
2.3 Signal Connector Function Description
-Mode Selection
The module can provide three control mode options, respectively; constant power mode, constant
current mode, and constant voltage mode.
Use PIN 15 and PIN 16 together
-Constant Power Mode (CP Mode)
-Constant Voltage Mode (CV Mode)
-Constant Current Mode (CC Mode)
Notes:
1.
X is defined as the PIN is not connected
2.
All modules can only choose the same mode
3.
Constant current mode is the default shipped from factory
4.
This mod is not suitable for CC & CP mode