HI Power Supply User Manual
Technical Sales / Customer Service:
+1-818-338-
7788 • Email:
31328 Via Colinas Suite 102 • Westlake Village, CA 91362 USA •
24 / 31
● 0X
201
The 0x211 address is provided to the client. Each module has four input signals, which are Enable,
Disable, Mode, Mode1 signals, and 8 groups of modules have 32PIN GPIO signals. Figure 4.5
Figure 4.5
Mode Selection
Notes:
1.
The mode selection of module 1 and module 2 needs to be the same
2.
The mode selection of module 3 and module 4 needs to be the same
3.
The mode selection of module 5 to module 8 needs to be the same
Item
Module-1
Module-2
Module-3 Module-4 Module-5 Module-6 Module-7 Module-8
Mode
Bit3
Bit7
Bit11
Bit15
Bit19
Bit23
Bit27
Bit31
Mode1
Bit4
Bit8
Bit12
Bit16
Bit20
Bit24
Bit28
Bit32
Module1, Module2
ITEM
Bit3(GPIO3), Bit7(GPIO7)
Bit4(GPIO4), Bit8(GPIO8)
CC Mode
L
L
CV Mode
L
H
Module5, Module6, Module7, Module8
ITEM
Bit19(GPIO19) Bit23(GPIO23)
Bit27(GPIO27) Bit31(GPIO31)
Bit20(GPIO20) Bit24(GPIO24)
Bit28(GPIO28) Bit32(GPIO32)
CC Mode
L
L
CV Mode
L
H