PAGE 16
©2010 4Front Engineered Solutions, Inc. - APS Resource
AP4047 RA 11/10
INsTALLATION
DETAIL F
1
1
2
2
3
3
4
4
A
A
B
B
- CRITICAL QUALITY DIMENSION
TOLERANCES ARE IN INCHES
UNLESS OTHERWISE SPECIFIED
MATERIAL SPECIFICATION
DRAWN
MATERIAL#/PO#
PART DESCRIPTION
DRAWN DATE
JOB/REF NUMBER
SCALE
ISSUE
PART NUMBER
.X : 0.060
.XX : 0.030
.XXX : 0.010
FRACTIONAL : 1/16
DIAMETER : +0.015 / -0.005
ANGULAR : 1 DEG
B
6009078
PROXIMITY SWITCH INSTALLATION
KELLEY ARTD PROXY KIT
NTS
jaime.pulido
7/11/2006
UOM
N/A
The information contained herein is proprietary and confidential to
4Front Engineered Solutions
and is to be used solely for the
express purpose of consideration and development of the article described herein and may not be reproduced or disseminated without
the express written permission of 4Front.
E
Z
I
S
T
E
E
H
S
T
E
E
H
S
B
2
OF
1
COMMON PARTS KIT - PROXIMITY SWITCHES 6009078
QTY
DESCRIPTION
PART NUMBER
ITEM
4
HN-ANSI B18.2.2 - 1/4 - 20
214161
1
2
AC INDUCT PROX SWITCH, N/O, 18 MM
625040
2
1
CAP, KELLEY ARTD
6008289
3
2
Wire Strain Relief
521110
4
4
Cable Tie, Nylon - 8 1/4"
131475
5
1
2" X 4" JUNCTION BOX
6008982
6
1
2" X 4" J BOX COVER
6008987
7
2
TEK #12-14 X 3/4" UNC Self Tapping Screw
215702
8
2
ZIP TIE PANDUIT ANCHORS
131476
9
1
Artd On Deck Bracket
6008286
10
1
Artd On Deck Lip
6008288
11
1
CAP, MAINTAIN FLOAT/STORED SENSOR, V2
6000721
12
1
Cord - Molded Plug
712027
13
3
Wire Nut
161011
14
4
LW 1/4 MED ZINC PLD BULK
234281
15
1) INSTALL PROXIMITY SWITCHES USING THE ARTD BRACKETS 10.1 & 11.1 AS SHOWN ON FIG. 1 & 2
2) FASTEN BRACKETS TO DECK AND LIP USING NYLON LOCK NUT 1.1
3) USE 5.1 CABLE TIES TO HOLD THE WIRES AND 9.1 PANDUIT ANCHORS, RUN ALL WIRES TO THE REAR,
4) "J" BOX FIG. 3 TO BE FASTENED 29" MEASURED FROM THE BACK OF THE BEAM USING 8.1 SELF TAPPING SCREWS ON
BEAM LEFT OF THE HYDRAULIC CYLINDER
5) SEE FIG. 4 FOR THE ELECTRICAL SCHEMATIC
REV. HISTORY:
ECO #
DATE
BY
DESCRIPTION
APPROVAL
09-185
04/06/2010
JP
B REPLACED FASTENERS
2
2
Figure 25
10. Attach the adhesive backed cable tie mounts to the
underside of the deck. Clean the deck surface before
applying the mounts. Route and secure both sensor
cables through the cable tie mounts towards the junc-
tion box. See Figures 22 and 25.
11. Route the proximity switch cables through the remain-
ing strain relief and into the junction box. Shorten the
cables if necessary. See Figure 26.
12. Use wire nuts to connect the proximity cables to the
power cord leads. See Figure 27 for wiring diagram.
13. Install the junction box cover.
14. Connect the power cord to the control panel and wire
per the wiring diagram for the dock leveler control
panel. Install a receptacle at the rear of the pit; or
hardwire per local and national electrical codes.
Figure 26
Figure 27
PRS1: Closes 4° Below Dock,
Opens 4° Above Dock
PRS2: Closes When Lip is Pendant
Deck Sensor
625-040
Deck Position
(Below Dock)
PRS1
Lip Sensor
625-040
Lip Position
(Pendant)
PRS2
Power Cord
BRN
BRN
BLU
BLU
BLK
WHT
J BOX
NEMA 5 15P
GRN
WHT
BLK