![APS Resource HTC Kit Installation And Owner'S Manual Download Page 14](http://html1.mh-extra.com/html/aps-resource/htc-kit/htc-kit_installation-and-owners-manual_2956905014.webp)
PAGE 13
©2010 4Front Engineered Solutions, Inc. - APS Resource
AP4047 RA 11/10
WIRING DIAGRAMs
BLU
BRN
ORG
RED
WHT
BLK
YEL
208-230V, SINGLE PHASE, 50/60HZ
LEVELER MOTOR WIRING DETAILS
DOUBLE POLE
CIRCUIT BREAKER
(BY OTHERS)
10 AMP MAX
L1
GRN
L2
208-230V
1 PHASE
50/60HZ
PIT WALL
JUNCTION BOX
(BY OTHERS)
3/4 HP MOTOR HAS
AUTOMATIC THERMAL
OVERLOAD
CONTROL
STATION
NOTE: VISUALLY CONFIRM MOTOR TAG
BLACK
GREEN
WHITE
MOTOR
WHT
BLK
GRN
INCOMING POWER AND MOTOR WIRES TO
BE STRANDED 14 GA 75°C COPPER.
(TORQUE TO 9 LBS. - IN)
GROUND WIRES TO BE STRANDED 14 GA
75°C COPPER )TORQUE TO 35 LB.- IN)
WIRING PROVIDED BY CUSTOMER
WIRING PROVIDED BY APS RESOURCE
M
GRN
SUPPLY LINE
GRN
NEUTRAL LINE
CIRCUIT BREAKER
(BY OTHERS)
20 AMP MAX
WHITE
GREEN
BLACK
PIT WALL
JUNCTION BOX
(BY OTHERS)
CONTROL
STATION
110-115V
1 PHASE
50/60HZ
LEVELER MOTOR WIRING DETAILS
110-115V, SINGLE PHASE, 60HZ
NOTE: VISUALLY CONFIRM MOTOR TAG
M
BLK
GRN
WHT
BRN
ORG
RED
BLU
WHT
YEL
BLK
INCOMING POWER AND MOTOR WIRES TO
BE STRANDED 14 GA 75°C COPPER.
(TORQUE TO 9 LBS. - IN)
GROUND WIRES TO BE STRANDED 14 GA
75°C COPPER )TORQUE TO 35 LB.- IN)
MOTOR
3/4HP MOTOR HAS AUTOMATIC
THERMAL OVERLOAD
WIRING PROVIDED BY CUSTOMER
WIRING PROVIDED BY APS RESOURCE
GRN
110-115V, single Phase, 50/60HZ
208-230V, single Phase, 50/60HZ
¾
¾
Before doing any electrical work, make certain
the power is disconnected and properly tagged or
locked off. All electrical work must be done by a
qualified technician and meet all applicable codes.
If it is necessary to make troubleshooting checks
in side the control box with the power on, USE
EXTREME CAUTION. Do not place your fingers or
uninsulated tools inside the control box. Touching
wires or other parts inside the control box could
result in electrical shock, death or serious injury.