10
www.Aprimatic.it
Fix the articulated arm to the automation (
use the screw M8 x 50
), and fix the other end of the articulated arm to the door.
Move the door in the closed position, and adjust the length of the half
‐
arm [A] so that the angle between the two half
‐
arms
[A] and [B] is the greater possible.
(*) To increase the opening force it is possible to reduce the angle and reduce the measurement of fixing of the articulated
arm, as shown in figure.
PRE
‐
CHARGING OF THE CLOSING SPRINGS
Tighten the screw [a] and compress the springs of about X = 5 mm, as shown in the figure.
Move the door manually, and verify the correct opening and closing force.
Install the opening mechanical stop (not supplied by us).
Note: the mechanical stop on the floor must be fixed in a visible position and must not create tripping hazard.
CLOSING OF THE AUTOMATION COVER
Attach the cover profile to the base profile. To prevent the cover from being opened without the use of a tool, you can
secure the cover to the heads at the holes, using the screws 2,9 x9,5 not supplied by us.