29
www.Aprimatic.it
10. ADJUSTMENT OF THE KINETIC ENERGY OF THE DOOR
To reduce the kinetic energy of the door make the following adjustments:
‐
adjust the force PUSH
≤
5;
‐
adjust the opening speed (VOP) so as to open the door (from 0° to 80°) at the times indicated in the table;
‐
adjust the closing speed (VCL) so as to close the door (from 90° to 10°) at the times indicated in the table.
Door weight
Door width
50 kg
60 kg
70 kg
80 kg
90 kg
0,75 m
3,0 s
3,0 s
3,0 s
3,0 s
3,5 s
0,85 m
3,0 s
3,0 s
3,5 s
3,5 s
4,0 s
1,00 m
3,5 s
3,5 s
4,0 s
4,0 s
4,5 s
1,20 m
4,0 s
4,5 s
4,5 s
5,0 s
5,5 s
11. TROUBLESHOOTING
In addition to the following list of possible problems, there are warnings provided by the display, as described in chapter 8.5.
Problem
Possible causes
Remedy
No power supply (display off).
Check the power supply.
Short circuited external accessories.
Disconnect all accessories from terminals 0
‐
1
and reconnect them one at a time (check for
voltage 12V).
The automation does not
open or close.
The door is locked by bolts and locks.
Check the freely move of the doors
Function selector incorrectly set.
Check and correct the settings of the function
selector.
The automation does not
perform the functions set.
Control devices or safety always
activated.
Disconnect devices from the terminal and verify
the operation of the door.
The movement of the doors
isn’t linear, or reverse the
movement for no reason.
The automation does not successfully
perform the automatic learning.
Perform a reset using the command 1
‐
29 , or
power off and power on the automation.
Anomalies during the safety devices
test.
Jumper contacts one at a time 41
‐
6A , 41
‐
8A.
The opening devices are activated.
Verify that the opening sensors are not subject
to vibration , do not perform false detections or
the presence of moving objects in the field of
action.
The automation opens but
does not close
The automatic closing doesn’t work.
Check the settings of the function selector .
Safety devices not activating.
Incorrect connections between the
safety devices and electronic control.
Check that the safety contacts of the devices
are properly connected to the terminal blocks
and the relative jumpers have been removed.
The automation opens by
itself.
The opening and safety devices are
unstable or detect moving bodies
Verify that the opening sensors are not subject
to vibration , do not perform false detections or
the presence of moving bodies in the field of
action.