Display Description
Factory settings
HOLD
Setting the push of keeping the door open. Choose between the following values:
NO = no push
MIN = light push
MED = medium push
MAX = heavy push
MIN
T41
Enable test for safety devices (in accordance with EN 16005). Choose between the following values:
NO = test disabled
YES = test enable
YES
MOT
Setting the manual friction of the door, by means of the electrical connection of the motor windings.
Choose between the following values:
OC = manual door opening without friction (motor with open circuit windings)
SC = manual door opening with friction (motor with short
‐
circuit windings)
SC
SIGN
Door position indication through the 0
‐
G2 output (see menu: ADV > STG2 > SIGN). Choose between the
following values:
CLOS = closed door
OPEN = open door
CLOS
TAKO
Open door time setting, after the 1
‐
KO command. Choose between the minimum and maximum:
minimum value = 1 s
maximum value = 30 s
NO = the door is always open
NO = see MENU > TAC
NO
SYNC
Door with 2 leaves, setting of master
‐
slave synchronization. Choose between the following values:
NO = no synchronization (door with 1 leaf)
MAST = automation which opens first
SLAV = automation which closes first
NO
SDLY
Door with 2 leaves, setting of delay of movement between Master
‐
Slave. Choose between the following
values:
NO = leaves without overlap
MIN =
minimum delay
MED = medium delay
MAX =
maximum delay
MED