49
11.3 FILTERING STATUS
The three Leds indicate the state of filtering efficiency and therefore only go on when filtration is activated;
only one Led lights up at a time. The indications on filtering status are:
- MAINTENANCE
(red Led):
- PRE-ALARM
(yellow Led):
- FILTER OK
(green Led):
saturated filter to be cleaned or replaced
(maintenance); in this case all the filtering
functions are stopped.
efficient filtering but not at the maximum
levels (pre-alarm)
high filtering efficiency
11.4 INFRARED REMOTE CONTROL UNIT
The remote control unit allows you to control the machine, modifying the air flow from a distance of
about 6-7 metres. The following functions are provided:
- 1st FAN SPEED key:
- 2nd FAN SPEED key:
- 3rd FAN SPEED key:
- OFF key:
sets the “maintenance” flow
(room half empty)
sets the “normal use” flow
(room half-full)
sets the “emergency” flow
(room crowded)
turns off the air purifier
How to use: point the remote control towards the control panel, taking care that you are in line with it at a
distance no greater than 6-7 metres.
When one of the four keys is pressed, the red LED at the top of the remote control unit goes on to indicate
that transmission is in progress. Almost at the same time, the red LED located in the receiver of the control
panel flashes, indicating that the signal has been received.
The infrared transmitter is powered by a 9-volt battery, type PP3 (transistor).
11.5 POWER SUPPLY AND ANTI BLACK-OUT SYSTEM
The machine is powered by a mains voltage of 210 to 240V AC at 50 Hz.
A momentary (or prolonged) power failure does not cause the resetting of the machine functions and when
power is restored the machine goes back into operation on its own.
ATTENTION: always connect the apparatus to the earth to protect persons, things and animals and
respect CEI 11-29, CEI 64-8, and EN 60335 standards.
Feb
. 12
Automatikprodukter