27
5.7.2 Connecting cables for power and micro switch
The satellite unit is connected to the pilot unit for power and micro switch.
For power, use normal 3G1.5 cable and proceed :
1) The pilot and satellite units must have contact plates as shown below and described previously.
2) Connect terminals 4-5-6 of the pilot unit to terminals 4-5-6 of satellite unit 1
Pilot unit contact plate
Satellite unit contact plate
3) In cases where a second satellite unit is required, connect terminals 4-5-6 of satellite 1 to terminals 4-5-6
of satellite 2
4) Use a 4G1 cable to connect the micro switch of the pilot unit utilizing terminals 7-8-9-10-11-12 on the
contact plate of satellite unit 1 (and satellite 2 if installed) following the electrical diagrams.
5) In cases where satellite re oxygenizing units are installed use a 3G1.5 cable to connect satellite filter unit
1 to satellite re oxygenizing 1, according to previous paragraph. Repeat for second satellite unit if
installed.
6) When done, close all covers.
7) Start the machines.