Bitek Technology
ANYTRON ANYCUT1 User Manual
© 2016 Bitek Technology. All rights reserved.
User Document
Rev 1.0.0 – 2016.03.06
69 of 120
10
Select the On in Vision On/Off
menu and enter the values for X
and Y.
(X = Width, -0.059 / Y = Height,
-0.070)
* Insert (-) mark when it enters
values.
* When using the black mark
that has the same size and a
type, it does not need to register
the vision mark again.
※ When the machine is delivered, the 3x3mm vision mark is already set in the machine and software,
if users use the same vision mark with that, they can only do step 3.2.3.1 in this manual.
※ How to Upload Firmware of Vision
Since the vision firmware is already uploaded when the machine is delivered, a user does not need to do
it seperately. However, if they have to upload the vision firmware unavoidably, Auto VISION Software
should be closed and be run. Also, if the firmware uploading is stopped abnormally when is terminated
during uploading the firmware or the power of PC is turned off or etc., it can affect the vision camera.
1
Start > Microscan AutoVISION >
Tools > Device Firmware Update