![AnyTone NSTIG-8R User Manual Download Page 51](http://html1.mh-extra.com/html/anytone/nstig-8r/nstig-8r_user-manual_2948982051.webp)
43
FUNCTION MENU SETUP
Squelch level setup
This function is used to setup open the squelch of receiving signals, the transceiver
will only allow calls when the receiving signal strength hits a minimum strength
clarity, otherwise, the transceiver will remain muted.
1. Press
key, the top left corner of the LCD will display " " icon, then press
key to enter into
function menu.
2. Press
/
key to choose NO. 22 function item, it shows "
SQL
" on LCD.
3. Press
key to enter next menu, and press
/
key to choose desired setting.
00~09 :
There are 10 levels of squelch in total, "00" is the minimum setup value (normally open)
4. Press
key or
key to confirm and exit.
Scanning Resume Time Setup
There are four kinds of scanning dwell time.
1. Press
key, the top left corner of the LCD will display " " icon, then press
key to enter into function menu.
2. Press
/
key to choose NO. 23 function item, it shows "
SCAN
" on LCD.
3. Press
key to enter next menu, press
/
key to choose desired setting.
5ST:
When scanning matched signal, transceiver will stop scanning for 5seconds then resume.
10ST:
When scanning matched signal, transceiver will stop scanning for 10seconds then resume.
15ST:
When scanning matched signal, transceiver will stop scanning for 15seconds then resume.