12
Issue 2 14/07/16
2
Technical Data
2.4 HIflo Range (LPG)
Andrews Model No.
L32/143 L65/169 L81/251 L62/309 L54/399
Storage Capacity
I
145
295
386
282
245
Recovery thro’ 44°C
I/h
649
788
1140
1403
1812
Recovery thro’ 56°C
I/h
517
613
913
1122
1449
Recovery thro’ 72°C
I/h
399
472
699
862
1117
Heat Input Gross
kW
41.8
49
76
92.5
122
Heat Input Net
kW
38
44
69
84
111
Gas
LPG CAT I
3
Gas Inlet Pressure Propane
mbar
37
37
37
37
37
Gas Inlet Pressure Butane
mbar
28
28
28
28
28
Gas Flow Rate Propane
m
3
/h
1.61
1.89
2.93
3.58
4.71
Gas Flow Rate Butane
m
3
/h
1.26
1.48
2.29
2.79
3.68
Gas Connection
Rc (in BSP Int) 3/4
3/4
3/4
3/4
3/4
Flue Gas Temp.
°C
125
125
170
190
170
Flue Gas Volume
m
3
/h
57
67
104
126
167
Gas Injector Orifice Diameter
mm
1.60
1.70
1.85
1.78
1.78
Flue Size (Secondary)
mm
150
150
200
200
250
Cold Water Feed Connection
R (in BSP/Exl)
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
Hot Water Flow Connection
R (in BSP/Exl)
1 1/2
1 1/2
1 1/2
11/2
1 1/2
*Return Connection
Rp (in BSP/Exl) 3/4
3/4
3/4
3/4
3/4
Drain Port Size
R (in BSP/Exl)
3/4
3/4
3/4
3/4
3/4
Max. Working Water Pressure (vented) bar
10.3
10.3
10.3
10.3
10.3
Max. Working Water Pressure (unvented) bar
5.5
5.5
5.5
5.5
5.5
Max. Test Pressure
bar
20.7
20.7
20.7
20.7
20.7
Weight Empty
kg
190
200
289
257
269
Weight Full
kg
335
488
656
618
514
Shipping Weight
kg
199
230
316
287
293
Shipping Dimensions Depth
mm
902
914
914
914
914
Shipping Dimensions Width
mm
768
762
762
762
762
Shipping Dimensions Height
mm
1270
1960
2210
1960
1960
* If the water heater is to be used on an unvented system, the combined temperature/ pressure
relief valve must be fitted directly into the tank. The secondary return is then connected to the
drain port via a suitable tee.
Summary of Contents for 24/39
Page 1: ......
Page 112: ...112 Issue 2 14 07 16 ...
Page 113: ...Issue 2 14 07 16 113 ...
Page 114: ...114 Issue 2 14 07 16 ...