10 Appendix
10.8 Service procedure D24-IV
Warning
Heater components may be HOT when performing the
following steps in this procedure. Take necessary
precaution to prevent personal injury.
10.8.1 Main burner & pilot removal and inspection
Main burner removal
Step 1. Disconnect (un-plug) water heater from electrical
supply.
Step 2. Turn “OFF” gas supply to water heater.
Step 3. Rotate gas valve control knob to the “OFF” position.
Step 4. Disconnect Gas supply line from the gas valve.
Step 5. Disconnect wire leads from gas valve.
Step 6. Disconnect white flame sense wire & orange ignition
wire from Control Board.
Step 7. Remove the two burner rack mounting screws.
Step 8. Slide complete burner rack out from heater.
Step 9. To install burner, reverse above procedure.
Step 10.Check for gas leaks and verify proper operation.
Main burner inspection
Step 1. Burner tubes should be free of any flue scale or other
debris. Clean burner tubes using a stiff brush and/or
shop vac. Burner ports should have uniform openings.
Replacement is recommended for burners where port
area is deteriorated or other unintended openings are
present.
Step 2. Insure pilot shield is in place.
Step 3. Inspect pilot position to insure smooth burner ignition
from pilot flame. Pilot should be mounted using the two
mounting screws through the burner support bracket
resulting in a level
pilot position.