background image

 

12 

5.5.  Drive connection to the electric network  

During the first connection of the drive to the electric network: 

 

Make sure that the rail carriage is blocked. 

 

Connect the plug of the drive feeding cable with the outlet of supply network. 

 

Immediately after connection of the plug and the outlet there will be a short light from the 
lamp  (lightening), the indicator  on  the  drive  control  panel  (Pic.  5)  will  show  the  numbers 
from «99» to «11». Then the drive will switch to the sleeping mode (the indicator will show 
«--»). If the indicator does not show the symbol switch off the drive from the network and 
carefully examine all connections (see he part «Malfunctions and recommendations on their 
elimination»). 

 

If the drive is connected with photo cells it is necessary to check the receiver (RX). If the 
indicator of the receiver blinks or does not glow it means that there is no signal of it is in-
terrupted due to inaccurate adjustment of the photo cells. The option of photo cells applica-
tion must be activated beforehand (see part «Adjustment»). 

6.  Adjustment 

Drive adjustment is performed through the control panel (Pic. 5) which has four buttons and 
an indicator (double 7-segment indicator). 

CODE

SET

UP

DOWN

 

Pic. 5. Control panel 

Table 4. Functions of buttons on the control panel 

Button 

Function 

SET 

Choice and confirmation of the function

 

UP 

Increase  of  the  parameter  during  programming  and  ad-

justment;  controls  the  doors  opening  while  adjustment  of 
final positions

 

DOWN 

decrease  of  the  parameter  during  programming  and  ad-

justment;  controls  the  doors  closing  while  adjustment  of 
final positions

 

CODE 

Programming and  deleting of the radio control panel

 

6.1.  Adjustment of final positions 

Adjustment of final positions of door opening/closing is performed manually (Table 5). 

 

 

 

 

 

 

Summary of Contents for ASG1000/3KIT

Page 1: ...ASG KIT ASG600 3KIT ASG1000 3KIT ASG1000 4KIT Installation and operation manual Sets series ASG KIT for automation of garage doors...

Page 2: ...Rail fixing to the wall above the doors Rail fixing to the ceiling Connection of carriage and door curtain ELECTRIC SUPPLY SYSTEM Photo cells installation Control buttons installation Other devices in...

Page 3: ...not responsible for any damage caused with unauthorized changes of the product or its misuse While installation and operation make sure that there are no lien objects water or oth er liquid inside the...

Page 4: ...tric supply unit 2 1 Scope of supply Table 1 contains the list of elements supplied Table 1 Scope of supply Item Quantity pcs 1 Drive 1 2 Installation and operation manual 1 3 Radio control panel 2 4...

Page 5: ...h force exerted rating cycles h 8 10 6 Lighting lamp illumination 24 10 base 15 Rail length m 3 2 4 2 Maximal doors height m 2 4 3 4 Maximal doors area m2 8 4 12 16 Protection class I Protective class...

Page 6: ...s and the surfaces are strong enough Make sure that there are no lien objects water or other liquid inside the drive and its other open parts Make sure that the drive and its components are positioned...

Page 7: ...he positions 21 and 22 4 1 Assembling of the drive rail The rail is supplied semi assembled To complete the assembling view Pic 2 follow the in structions Adjust the top of the carriage 5 to the botto...

Page 8: ...A B C D F G F D G C A B 4 15 5 21 4 1 9 17 8 13 18 22 10 14 15 30 22 12 16 11 20 19 6 7 35 55 17 Pic 2 Set installation...

Page 9: ...east 50 mm lower than the horizontal bottom end of the rail Adjust the fixing bracket of the rail 8 at the chosen place on the wall in the horizontal posi tion in the middle of the doors using three d...

Page 10: ...6 and forward thrust 7 using two bolts 14 and two nuts 18 regu lating the common length by choosing the appropriate apertures Using axes 19 and cotters 20 fix one end of combined rod on the carriage a...

Page 11: ...ntrol the drive they must be connected parallelly Control devices must be positioned within sight of the doors at a safe distance from the mova ble parts at a height not less than 1 5m 5 3 Other devic...

Page 12: ...If the indicator of the receiver blinks or does not glow it means that there is no signal of it is in terrupted due to inaccurate adjustment of the photo cells The option of photo cells applica tion m...

Page 13: ...efine the level of power while closing the doors When this level of power is achieved the drive stops and opens the doors in case there is an accidental obstacle for example a vehicle or a man The adj...

Page 14: ...ing b 5 To confirm the chosen value press button SET after that the drive will be adjusted in the waiting mode D Adjustment of electronic blocking 1 Press and hold button SET for 5 seconds 2 When you...

Page 15: ...m the memory of the control unit and program them once again to avoid the illegal intrusion into the premises 7 TESTING AND COMMISSIONING This is the most important stage of drive system installation...

Page 16: ...t label or sign with the description of unblocking and manual opening of the doors Adjust near the doors at a visible place the permanent safety label containing the following text Attention Automatic...

Page 17: ...curacy of doors final positions If required re program final positions Clear the external surface of the drive and safety devices using soft damp cloth It is forbidden to use for cleaning water stream...

Page 18: ...arriage Add the necessary quantity of lub ricant In the process of operating the chain vibrates and pounds on the track The chain is not tightened Ensure the required tension of the chain if necessary...

Page 19: ...elephone of the supplier mounting company Mounting questionnaire Customer address _________________________________________________________ ____________________________________________________________...

Page 20: ...ing Date of mounting _______________________________ date month year Signature of person responsible for mounting _______________________________ signature MP _______________________________ Decipheri...

Page 21: ...sters damages of the product construction caused by the customer or third person defects and damages caused by the absence of the regular technical support and examine of the product Note the removed...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Reviews: