background image

 

11 

-

+

BAT

-

+

+24V PE GND PB

C

O

M

N

O

-

+

-

+

C

O

M

N

C

RX

TX

фотоэлементы

кнопка 

управления

аккумулятор

 

Pic. 4. Electric supply system 

5.1.  Photo cells installation 

To ensure the security the drive may have photo cells. Output circuit of the receiver (RX) must 
be  connected  with  the  terminals  «PE»

 

and  «GND».  Power  circuit  of  the  receiver  (RX)  and 

transmitter (TX) of photo cells are connected with the terminals «+24V» and «GND». 
If there are several pairs of photo cells they must be connected one with another consecutively 
in the output circuit and parallel in the power circuit.  
When the doors are closing photo cells interrupt their movement and initiate further opening of 
the doors. 

5.2.  Control buttons installation 

To control the drive in the step-by-step mode (corresponds to the sequence …Open – Stop – 
Close – Stop…) there is a possibility to connect devices with “normally open contacts”: buttons, 
locking switches, etc.  
Connection of the control button (or buttons) is performed to the terminals «PB» and «GND». 
If there are several buttons installed to control the drive, they must be connected parallelly.  
Control devices must be positioned within sight of the doors at a safe distance from the mova-
ble parts at a height not less than 1,5m. 

5.3.  Other devices installation 

The  drive  can  be  also  connected  with  other  devices,  for  example,  universal  receiver  of  radio 
control, etc. These devices can be connected with the terminals «+24V» and «GND» with volt-
age 24В of direct current. Maximum level of current for all devices connected with the termi-
nals «+24V» and «GND» must not exceed 100mA. 

5.4.  Accumulator installation 

Accumulator  (accumulating  battery)  can  be  used  as  a  standby  power  supply  source  with 
24В/2,5А·h. The drive control panel automatically switches to the accumulator in case of ab-
sence  of  the  mail  power  supply  and  automatically  returns  to  the  mail  power  supply  when  it 
starts functioning. The drive control panel controls the battery charge. 

!

 

If the connection of additional devices (for example accumulator) is performed after 
commissioning of the drive system re-program the final positions of the doors  (see 
part «

A

djustment of final positions») and check the drive system functioning. 

 

Photo cells 

Control button 

Accumulator 

Summary of Contents for ASG1000/3KIT

Page 1: ...ASG KIT ASG600 3KIT ASG1000 3KIT ASG1000 4KIT Installation and operation manual Sets series ASG KIT for automation of garage doors...

Page 2: ...Rail fixing to the wall above the doors Rail fixing to the ceiling Connection of carriage and door curtain ELECTRIC SUPPLY SYSTEM Photo cells installation Control buttons installation Other devices in...

Page 3: ...not responsible for any damage caused with unauthorized changes of the product or its misuse While installation and operation make sure that there are no lien objects water or oth er liquid inside the...

Page 4: ...tric supply unit 2 1 Scope of supply Table 1 contains the list of elements supplied Table 1 Scope of supply Item Quantity pcs 1 Drive 1 2 Installation and operation manual 1 3 Radio control panel 2 4...

Page 5: ...h force exerted rating cycles h 8 10 6 Lighting lamp illumination 24 10 base 15 Rail length m 3 2 4 2 Maximal doors height m 2 4 3 4 Maximal doors area m2 8 4 12 16 Protection class I Protective class...

Page 6: ...s and the surfaces are strong enough Make sure that there are no lien objects water or other liquid inside the drive and its other open parts Make sure that the drive and its components are positioned...

Page 7: ...he positions 21 and 22 4 1 Assembling of the drive rail The rail is supplied semi assembled To complete the assembling view Pic 2 follow the in structions Adjust the top of the carriage 5 to the botto...

Page 8: ...A B C D F G F D G C A B 4 15 5 21 4 1 9 17 8 13 18 22 10 14 15 30 22 12 16 11 20 19 6 7 35 55 17 Pic 2 Set installation...

Page 9: ...east 50 mm lower than the horizontal bottom end of the rail Adjust the fixing bracket of the rail 8 at the chosen place on the wall in the horizontal posi tion in the middle of the doors using three d...

Page 10: ...6 and forward thrust 7 using two bolts 14 and two nuts 18 regu lating the common length by choosing the appropriate apertures Using axes 19 and cotters 20 fix one end of combined rod on the carriage a...

Page 11: ...ntrol the drive they must be connected parallelly Control devices must be positioned within sight of the doors at a safe distance from the mova ble parts at a height not less than 1 5m 5 3 Other devic...

Page 12: ...If the indicator of the receiver blinks or does not glow it means that there is no signal of it is in terrupted due to inaccurate adjustment of the photo cells The option of photo cells applica tion m...

Page 13: ...efine the level of power while closing the doors When this level of power is achieved the drive stops and opens the doors in case there is an accidental obstacle for example a vehicle or a man The adj...

Page 14: ...ing b 5 To confirm the chosen value press button SET after that the drive will be adjusted in the waiting mode D Adjustment of electronic blocking 1 Press and hold button SET for 5 seconds 2 When you...

Page 15: ...m the memory of the control unit and program them once again to avoid the illegal intrusion into the premises 7 TESTING AND COMMISSIONING This is the most important stage of drive system installation...

Page 16: ...t label or sign with the description of unblocking and manual opening of the doors Adjust near the doors at a visible place the permanent safety label containing the following text Attention Automatic...

Page 17: ...curacy of doors final positions If required re program final positions Clear the external surface of the drive and safety devices using soft damp cloth It is forbidden to use for cleaning water stream...

Page 18: ...arriage Add the necessary quantity of lub ricant In the process of operating the chain vibrates and pounds on the track The chain is not tightened Ensure the required tension of the chain if necessary...

Page 19: ...elephone of the supplier mounting company Mounting questionnaire Customer address _________________________________________________________ ____________________________________________________________...

Page 20: ...ing Date of mounting _______________________________ date month year Signature of person responsible for mounting _______________________________ signature MP _______________________________ Decipheri...

Page 21: ...sters damages of the product construction caused by the customer or third person defects and damages caused by the absence of the regular technical support and examine of the product Note the removed...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Reviews: