а
б
Pic. 3. Manual unblocking of the carriage
!
In the process of unblocking there can be uncontrolled movement of doors:
- if the door spring are loose or broken;
- if the doors are not balanced;
- if the doors are opened manually the carriage can collide with the drive (during build-
ing works limit the doors run in the opening direction);
- in the unblocked position doors can be moved only with medium speed!
4.2. Installation of the drive on the rail
To install the drive on the rail (view B, Pic. 2) follow the instruction:
Connect with slight push the rail end 4 and the drive 1 matching the aperture in the star
wheel and the drive shaft. The drive must be carefully installed on the rail. Little force
should be applied for not to damage the drive or spoil its exterior outlook.
Fix the rail to the drive with two U-shaped brackets 9, then tighten them with four nuts 17.
4.3. Rail fixing to the wall above the doors
To fix the rail to the wall above the doors (view C, Pic. 2) follow the instruction:
Define the positioning of the fixing bracket of the rail 8 on the wall above the doors. In the
highest point of the doors movement at the opening position the top end of door curtain
must be at least 50 mm lower than the horizontal bottom end of the rail.
Adjust the fixing bracket of the rail 8 at the chosen place on the wall in the horizontal posi-
tion in the middle of the doors using three dowels. If the bracket cannot be positioned in
the middle of the doors, it must be installed at a distance approximately 100mm to the
right or to the left from the middle of the doors. Use the dowels suitable for the material
and wall thickness.
Connect the rail with the drive and the fixing bracket of the rail 8 using two bolts 13 and
two nuts 17.
4.4. Rail fixing to the ceiling
To fix the rail to the ceiling follow the instruction:
Fix the U-shaped bracket of the rail 10 (view D, Pic. 2) and the bent fixing strip 22 on the
rail near the drive using two bolts 14 and two nuts 18.
If the distance from the rail to the ceiling is 5…130mm one fixing P-shaped strip is used
(Pic. 2).
If the distance from the rail to the ceiling is 130…350mm two fixing Z-shaped strips are
used (in this case there should be two additional fixing strips which are not included in the
scope of supply).
!
Depending on the fixing technique choose the most appropriate apertures on the
bent fixing strip. It is acceptable to cut off the unnecessary part of the fixing strip.
!
The rail with the drive can be installed directly on the ceiling. In this case the dis-
tance from the rail to the ceiling must be 5 mm.
Summary of Contents for ASG1000/3KIT
Page 22: ...22 Notes...
Page 23: ...23 Notes...