background image

 

10 

 

Position the fixing bracket of the  rail  12 (view F, Pic. 2) and the bent fixing strip 22 (de-
scribed above) on the rail at a place ensuring the highest rigidity of the rail (for example, at 
a distance 1/3 of the rail length from the door passage). Connect the fixing bracket of the 
rail and the fixing strip using two bolts 14 and two nuts 18.  

 

Using the ladder lift the rail with the drive so that the bent strips are pressed to the ceiling. 
Level the rail vertically and horizontally (is checked with the level). Mark four points for the 
dowels to adjust the rail to the ceiling.  

 

Adjust the dowels and fix the strips 22 to the ceiling. Use the dowels suitable for the mate-
rial and wall thickness.  
 

!

 

Fixing elements must hold the rail weight with the drive and resist the effort required 
for opening / closing of the doors. Take into account the objective wear and defor-
mations.  

4.5.  Connection of carriage and door curtain 

To connect the carriage of the rail and door curtain (view G, Pic. 2) follow the instruction: 

 

Connect the cranked rod 6 and forward thrust 7 using two bolts 14 and two nuts 18 regu-
lating the common length by choosing the appropriate apertures 

 

Using axes 19 and cotters 20 fix one end of combined rod on the carriage, adjust the door 
bracket 11 at the other end.  

 

Move the combined rod together with the carriage (first unblock the carriage) until the door 
bracket  11  touches  the  top  end  of  the  door  curtain.  Then  level  the  rod  and  fix  it  on  the 
doors using four self-tapping screws 16. 

 

5.  ELECTRIC SUPPLY SYSTEM 

!

 

Before starting the connection works make sure that the wiring is cut off.   

!

 

During operation and installation of electrical devices (accessories) it is obligatory to 
follow the present manual. Incorrect connection may fail the functioning of the drive.   

After installation of electrical devices it is necessary to connect them with the drive. Follow the 
instruction: 

 

Turn off four screws, remove the frame cover of the drive to open the access to the termi-
nals of the control panel. 

 

Using the drill make an aperture in the frame base, it is needed for laying cables from elec-
tric devices to the control panel. 

 

Using the screwdriver connect the electric conductors to the terminals of the drive control 
panel (Pic. 4) according to points 5.1 … 5.4. 

Summary of Contents for ASG1000/3KIT

Page 1: ...ASG KIT ASG600 3KIT ASG1000 3KIT ASG1000 4KIT Installation and operation manual Sets series ASG KIT for automation of garage doors...

Page 2: ...Rail fixing to the wall above the doors Rail fixing to the ceiling Connection of carriage and door curtain ELECTRIC SUPPLY SYSTEM Photo cells installation Control buttons installation Other devices in...

Page 3: ...not responsible for any damage caused with unauthorized changes of the product or its misuse While installation and operation make sure that there are no lien objects water or oth er liquid inside the...

Page 4: ...tric supply unit 2 1 Scope of supply Table 1 contains the list of elements supplied Table 1 Scope of supply Item Quantity pcs 1 Drive 1 2 Installation and operation manual 1 3 Radio control panel 2 4...

Page 5: ...h force exerted rating cycles h 8 10 6 Lighting lamp illumination 24 10 base 15 Rail length m 3 2 4 2 Maximal doors height m 2 4 3 4 Maximal doors area m2 8 4 12 16 Protection class I Protective class...

Page 6: ...s and the surfaces are strong enough Make sure that there are no lien objects water or other liquid inside the drive and its other open parts Make sure that the drive and its components are positioned...

Page 7: ...he positions 21 and 22 4 1 Assembling of the drive rail The rail is supplied semi assembled To complete the assembling view Pic 2 follow the in structions Adjust the top of the carriage 5 to the botto...

Page 8: ...A B C D F G F D G C A B 4 15 5 21 4 1 9 17 8 13 18 22 10 14 15 30 22 12 16 11 20 19 6 7 35 55 17 Pic 2 Set installation...

Page 9: ...east 50 mm lower than the horizontal bottom end of the rail Adjust the fixing bracket of the rail 8 at the chosen place on the wall in the horizontal posi tion in the middle of the doors using three d...

Page 10: ...6 and forward thrust 7 using two bolts 14 and two nuts 18 regu lating the common length by choosing the appropriate apertures Using axes 19 and cotters 20 fix one end of combined rod on the carriage a...

Page 11: ...ntrol the drive they must be connected parallelly Control devices must be positioned within sight of the doors at a safe distance from the mova ble parts at a height not less than 1 5m 5 3 Other devic...

Page 12: ...If the indicator of the receiver blinks or does not glow it means that there is no signal of it is in terrupted due to inaccurate adjustment of the photo cells The option of photo cells applica tion m...

Page 13: ...efine the level of power while closing the doors When this level of power is achieved the drive stops and opens the doors in case there is an accidental obstacle for example a vehicle or a man The adj...

Page 14: ...ing b 5 To confirm the chosen value press button SET after that the drive will be adjusted in the waiting mode D Adjustment of electronic blocking 1 Press and hold button SET for 5 seconds 2 When you...

Page 15: ...m the memory of the control unit and program them once again to avoid the illegal intrusion into the premises 7 TESTING AND COMMISSIONING This is the most important stage of drive system installation...

Page 16: ...t label or sign with the description of unblocking and manual opening of the doors Adjust near the doors at a visible place the permanent safety label containing the following text Attention Automatic...

Page 17: ...curacy of doors final positions If required re program final positions Clear the external surface of the drive and safety devices using soft damp cloth It is forbidden to use for cleaning water stream...

Page 18: ...arriage Add the necessary quantity of lub ricant In the process of operating the chain vibrates and pounds on the track The chain is not tightened Ensure the required tension of the chain if necessary...

Page 19: ...elephone of the supplier mounting company Mounting questionnaire Customer address _________________________________________________________ ____________________________________________________________...

Page 20: ...ing Date of mounting _______________________________ date month year Signature of person responsible for mounting _______________________________ signature MP _______________________________ Decipheri...

Page 21: ...sters damages of the product construction caused by the customer or third person defects and damages caused by the absence of the regular technical support and examine of the product Note the removed...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Reviews: