 WARNING 

 K.  MOTOR VEHICLE SAFETY/TRANSIT USE

Your chair has been manufactured with built-in Transport 

Brackets.

The standard transport brackets have not been crash-tested 

in accor dance with WC-19. Use these transport brackets 

only to secure an unoccupied wheelchair during transport

1.  NEVER let anyone sit in the wheelchair while in a 

moving vehicle.

2.  NEVER transport the wheelchair in the front seat of a 

vehicle. It may shift and interfere with the driver

3.  ALWAYS secure the wheelchair so that it cannot roll or shift.

4.  Do not use any wheelchair that has been involved in a 

motor vehicle accident

5.  Information concerning approved WC-19 tie down 

systems. Please consult available WC-19 manual

 

!

 WARNING  

 L.  CENTER OF BALANCE

The point where this chair will tip forward, back, or to the 

side depends on its center of balance and stability. The 

Center of gravity is affected by:

1.  The seat height and seat angle.

2.  A change in your body position, posture or weight 

distribution.

3.  Using this chair on a ramp or slope.

4.  The use of a back pack or other options, and the 

amount of added weight.

5.  Drive wheel positioning.

To Reduce The Risk Of A Fall Or Tip-Over:

Whenever a condition exists that may change the center of 

balance, reduce speed, proceed cautiously, and when in 

doubt, always have someone help you.

 

!

 WARNING  

 M. TRANSFERS

It is dangerous to transfer on your own. It requires good 

bal ance and agility. Be aware that there is a point during 

every trans fer when the wheelchair seat is not below you. 

To prevent a fall:

1.  Always turn off power before you transfer to or from your 

chair. If you fail to do so you may touch the joystick and 

cause your chair to move when you do not expect it.

2.  Make sure motor locks are engaged. This keeps the 

chair from moving when you transfer.

3.  Work with your health care professional to learn safe 

methods.

• Learn how to position your body and how to support 

yourself during a transfer.

• Have someone help you until you are sure you can 

do a safe transfer on your own.

4.  Move your chair as close as you can to the seat you 

are transferring to. If possible, use a transfer board.

5.  Rotate the front casters until they are as far forward as 

possible.

6.  Be careful of the footrests. If you can, remove or swing 

them out of the way.

• Never stand on footrests when you transfer. Doing so 

may damage them or cause your chair to tip.

• Make sure your feet do not “hang up” or get caught 

in the space between the footrests.

7.  Make sure armrests do not interfere.

8.  Transfer as far back onto the seat surface as you can. 

This will reduce the risk that you will miss the seat or 

fall. 

 

!

 WARNING 

 N. REACHING OR LEANING

Reaching or leaning affects the center of balance of your 

chair. If done improperly, a fall or tip-over is likely. When 

in doubt, ask for help or use a device to extend you reach.

To Reduce the Risk of injury and/or Damage to the Chair:

1.  Never reach or lean if you must shift your weight 

sideways or rise up off the seat.

2.  Never reach or lean if you must move forward in your 

seat to do so. Always keep your buttocks in contact 

with the backrest.

3.  Never reach with both hands (you may not be able 

to catch yourself to prevent a fall if you lose your 

balance).

4.  Never try to pick up an object from the floor by 

reaching down between your knees.

5.  Never put pressure on the footrests while reaching.

6.  Never reach or lean over the top of the seat back. This 

may damage the backrest and cause you to fall.

t

 VI. GENERAL WARNINGS

Summary of Contents for R HybridHybrid

Page 1: ...Rev 01 February 2017...

Page 2: ...this owner s manual please contact your dealer or qualified technician before oper ating this AmySystems wheelchair Failure to do so may result in damage and or injury DEALER TECHNICIAN WARNING WARNI...

Page 3: ...6 H Maintenance Chart 36 I Ordering Parts 36 XII AmySystems LIMITED WARRANTY 37 1 Limited Warranty 37 2 Replacement Parts Warranty 37 3 Return Policy 37 4 Restocking Fee Policy 37 XII DISCLAMER AND WA...

Page 4: ...able from 24 to 26 610 mm and 660 mm Custom width available 1 Headrest 2 Push Handle 3 Armrest 4 Seat Frame 5 Free wheel Release Lever 6 Base Frame 7 Drive Wheels 8 Caster Fork 9 Caster Tire 10 Foot P...

Page 5: ...chair Consult your supplier and your health care professional to help you choose the best set up and options for your safety XI BATTERIES Here you will learn about battery and charger safety and how...

Page 6: ...even if they are not in use These include two way radios used in police cars fire trucks ambulances and taxi cabs The antenna is usually mounted on the outside of the vehicle 3 Long Range Transceiver...

Page 7: ...fall tip over or loss of control may occur and cause severe injury to you or others A NOTICE TO USER AND ATTENDANTS WARNING USER 1 Before using this chair you should be trained in its safe use by your...

Page 8: ...total weight user plus additional weights exceeds weight capacity 3 Exceeding the weight limit is likely to damage the seat frame or fasteners and may cause severe injury to you or others from chair f...

Page 9: ...or sauna Do not use your chair in fresh or salt water such as at the edge of a stream lake or ocean Make sure the battery post covers are secured Replace joystick boot if it becomes torn or cracked Ma...

Page 10: ...e joystick and cause your chair to move when you do not expect it 2 Make sure motor locks are engaged This keeps the chair from moving when you transfer 3 Work with your health care professional to le...

Page 11: ...eed 2 Stop often and check to make sure your path is clear of obstacles WARNING R RAMPS SLOPES SIDEHILLS The center of balance of your chair changes when you are on a slope NOTE Slope includes a ramp...

Page 12: ...ause a fall or tip over When in doubt have someone help you 3 Always position the user securely in the chair to help prevent falls while on a lift 4 Avoid moving forward if a wheel is hung up on the l...

Page 13: ...4 See Section VIII Set Up Adjustment Use for proper torque settings WARNING E FOOTRESTS 1 At the lowest point footrests should be at least 1 1 4 32mm off the ground If set too LOW they may hang up on...

Page 14: ...ce 3 The belt must be snug but must not be so tight that it interferes with breathing You should be able to slide your open hand flat between the belt and your stomach 4 Make sure you can easily remov...

Page 15: ...ng system configuration Doing so could result in premature failure or injury and could void the waranty of your wheelchair 7 Latch Mode While operating any power seating function in latched mode use c...

Page 16: ...can Loose bolts or screws can cause damage to other chair parts causing them to fail 4 Washers Spacers Note the position of washers and spacers before disassembly To avoid damage to the frame replace...

Page 17: ...to put the batteries back in WARNING Batteries may weigh up to 55 lbs 25 kg each Care must be taken to avoid injury when lifting B SWING AWAY FOOTRESTS fig 3 4 1 Installation fig 3 a Place swing away...

Page 18: ...Move calf pad to desired height c Tighten bolts E JOYSTICK Please refer to the PG Drives user s manual provided with the information package F TO ADJUST THE DEPTH OF THE JOYSTICK fig 3 1 Loosen the w...

Page 19: ...s the inside of the chair then lift WARNING Reinstall the bolts and tighten all the bolts securely H DUAL POST HEIGHT ADJUSTABLE ARM RESTS fig 5 The dual post flip back armrest can be used as either a...

Page 20: ...wheelchair slightly back and forth and or push against the chair while moving the lever IX OPERATING GUIDE A BATTERY CABLE AND FUSES fig 1 Your AmySystems Alltrack is equiped with 3 MIDI style 70A fus...

Page 21: ...will be a long beep The wheelchair is now locked NOTE The following screen will be displayed the next time the Control System is switched on To unlock with keypad R Net and VR2 Press the power button...

Page 22: ...backward to activate the power option and deflect the joystick forward to return to the static mode G PERFORMANCE CONTROL SETTINGS NOTE Seek advice regarding checking and adjusting settings It is vit...

Page 23: ...r tilt system serviced by an authorized dealer or qualified technician J POWER TILT Standard Operating Instructions WARNING Make sure the wheelchair is on a level surface before proceeding with tilt m...

Page 24: ...stick forward until the desired height is achieved then release 3 DRIVING IN REDUCED SPEED Reduced drive is a feature designed to allow the user to drive the wheelchair at a reduced speed while lifted...

Page 25: ...itch forward in the same direction until you achieve the desired tilt angle then release L POWER TILT SEAT ELEVATE COMBO Standard Operating Instructions 3 DRIVING IN REDUCED SPEED Reduced drive is a f...

Page 26: ...nd and push the four way toggle switch forward until the desired tilt angle is achieved and release PUSH BUTTON SWITCHES Increasing Tilt Angle Push the 1st button furthest from the wire until the desi...

Page 27: ...TING GUIDE u WARNING Make sure the wheelchair is on a level surface before proceeding with recline mode 4 WAY TOGGLE Increasing Recline Angle Pull the four way toggle switch back until the desired rec...

Page 28: ...desired legrest angle is achieved and release 4th push button switch O POWER ELEVATING FRONT RIGGINGS Standard Operating Instructions WARNING Make sure the wheelchair is on a level surface INCREASING...

Page 29: ...EASING DECREASING THE POWER CENTER MOUNT 4 way Toggle Move the four way toggle switch towards the left side of the wheelchair until the desired center mount angle is achieved To reverse the center mou...

Page 30: ...Set at desired angle There are ten holes in 4 incre ments to choose from P ADJUSTMENTS WARNING At all times the screws on each side holding the back canes must be screwed in tight and secured in orde...

Page 31: ...work properly Wrong Programming Wrong Cable Plugging Drive defeat switch is unplugged or defective Reduced speed switch is unplugged or defective Mercury switch is unplugged or defective Verify prope...

Page 32: ...al system may fail and result in severe injury or death of user B BATTERY CHARGER A battery charger produces a direct current DC When applied to a discharged battery this reverses the chemical reactio...

Page 33: ...1 Connect and disconnect battery cables with caution Con nect the red lead to the positive terminal and the black lead to the negative terminal Do this for each battery 2 For batteries with post tigh...

Page 34: ...peak perform ance and to avoid injury from chair failure damage or premature wear 2 Inspect and maintain this chair strictly per the Maintenance Chart 3 If you detect a problem make sure to service or...

Page 35: ...ted tire may burst 4 Never use a gas station pump to inflate a tire Such pumps provide air at high volume and may cause tire to burst 5 Check for signs of wear and correct air pressure in pneu matic t...

Page 36: ...upplier X I ORDERING PARTS When you order parts provide the following 1 Model of chair 2 Serial number of chair 3 Left hand or right hand control 4 Part number description and quantity of parts you ne...

Page 37: ...te 1 Six 6 months All Electronic Components and Actuators Note 1 Thirty 30 days Upholstery Plastic or Rubber parts and Painted Surfaces due to poor adhesion Note 1 Thirty 30 days All other Original Co...

Page 38: ...IMITATIONS AND EXCLUSIONS The foregoing warranty shall apply only to the original purchase and shall not apply to serial numbered products if the serial number has been removed or defaced products sub...

Page 39: ...39 Manufactured by Amylior Inc DBA AmySystems 3190 F X Tessier Vaudreuil Dorion QC J7V 5V5 Canada Phone 1 450 424 0288 T F 1 888 453 0311 Email info amysystems com...