Serial Control Strings
62
Mi Series and Tango Audio Controllers
Command Messages
Command Messages
MVER
Get Firmware Version
Firmware Version Status:
"MVERMxxx"
where:
'xxxx' denotes the current firmware version.
- or -
ERR
MGCF
Get Configuration
Configuration Status:
"MCFrr,s,zz,c"
where:
1) 'rr' is the number of rooms connected, valid
values are 2-64
2) 's' is the number of sources connected, valid
values are 4,6,8
3) 'zz' is the number of zones available, valid
values are 1 or 'rr'/2
4) 'c' is the clock available status, where:
0 : no clock installed
1 : clock module is present
- or -
ERR
FNIC
Get Number of IIC devices
Num IIC Devices Status:
"FNICxx"
where:
'xx' denotes the number of IIC devices avail-
able in the MRC.
- or -
ERR
FGICx
Get IIC Device Status
where:
'x' is the IIC device index, valid values range
from 1 to the number of
available IIC devices as reported in the 'Num
IIC Devices Status'.
IIC Device Status:
"FSICxx,aaa,vvvv,pppp,ddddd"
where:
1) 'xx' is the IIC device index, valid values
range from 1 to the number of IIC devices as
denoted in the
'Num IIC Devices Status'
2) 'aaa' is the device ID
3)'vvvv' is the version
4) 'pppp' is the product ID
5) 'ddddd' is a descriptive string for the device,
the string is of variable length
- or -
ERR
Summary of Contents for Tango DAS-T0804-SIG
Page 4: ...IMPORTANT SAFETY INSTRUCTIONS b Tango Series Audio Controllers...
Page 12: ...viii Tango Series Audio Controllers Table of Contents...
Page 16: ...Tango Series Audio Controllers 4 Tango Series Audio Controllers...
Page 50: ...Setup and Configuration 38 Tango Series Audio Controllers...
Page 101: ...Troubleshooting 89 Tango Series Audio Controllers...