Pre-Installation
8
PTE-300 PosiTrack Ethernet Camera Controller
The LED below and to the right of the joyswitch, LED1, may give one of several signals for the operator:
RS-232 communications settings
The factory default RS-232 communications settings are:
9600 baud
No Parity
8 bits
1 stop bit
The PTE-300 contains one EIA RS-232C standard port for equipment that requires RS-232 control. The
following communication protocols are supported:
300, 2400, 9600, 19200, and 38400 baud
7, 8, or 9 Data bits
1 or 2 Stop bits
Even, Odd, and None parity settings
RS-232 Port DB-9 pinouts
The following table lists the RS-232 Port DB-9 (male) pinouts (FIG. 10).
LED1 Signals
Flashes
Status
Once per second
Normal operation: Network control mode
Twice per second
Normal operation: Local mode
Once every 4 seconds
Issue: Firmware not uploaded, and only boot firmware installed.
FIG. 10
RS-232 Port DB-9 (male) pinouts
RS-232 Port DB-9 (male) Pinouts
Pin Signal
1
N/A
2
RXD - Receive Data Input
3
TXD - Transmit Data Output
4
N/A
5
GND - Ground
6
N/A
7
RTS - Ready To Send Output
8
CTS - Clear To Send Input
9
N/A
9
8
7
6
5
4
3
2
1
9
8
7
6
Female
Male
Summary of Contents for PTE-300
Page 24: ...Installation 20 PTE 300 PosiTrack Ethernet Camera Controller ...
Page 28: ...COMM Module Implementation 24 PTE 300 PosiTrack Ethernet Camera Controller ...
Page 32: ...Upgrading the Firmware 28 PTE 300 PosiTrack Ethernet Camera Controller ...
Page 42: ...Web Configuration Interface 38 PTE 300 PosiTrack Ethernet Camera Controller ...
Page 43: ...Web Configuration Interface 39 PTE 300 PosiTrack Ethernet Camera Controller ...