45
USER MANUAL
DCP-MTX
IDX
Function Description
More Details
Syntax
Example
20
Get CEC Auto Power Status
Command:
SSPAT
Return:
SSPAT( value )
Parameter:
※
value = {0, 1} // {0, 1}:{off, on}
Description:
Get Sink auto power Function ON or
OFF Status.
Command:
SSPAT
Return:
SSPAT( 1 )
Description:
Sink auto power status is ON.
21
Set CEC Power Delay Time
Command:
CD#SPT
Return:
CD#SPT
Parameter:
※
D# : # = {0, 1, …30}
Description:
Set CEC Power Delay Time.
Command:
CD2SPT
Return:
CD2SPT
Description:
CEC Power Delay Time is 2 min.
22
Get CEC POWER Delay Time
Status
Command:
SDSPT
Return:
SDSPT( value )
Parameter:
※
value = {0, 1, …30}
Description:
Get CEC POWER Delay Time Status.
Command:
SDSPT
Return:
SDSPT( 2 )
Description:
CEC Power Delay Time is 2 min.
23
Set UART Baud Rate
Command:
CUBD#T
Return:
CUBD#T
Parameter:
※
SOR# : # = {9600, 19200, 38400,
57600, 115200}
Description:
Set UART Baud Rate.
Command:
CUBD115200T
Return:
CUBD115200T
Description:
UART Baud Rate is 115200.