• Stop Bits: Set the Stop Bits for the device connected to the RS232 port.
• Hex String: Switch the button ON to turn the RS232 commands to Hexadecimal
format.
• End Flag: Click to choose the end flag for the RS232 commands.
• RS232 Auto Control: Click to enable or disable RS232 Auto Control. When enabled,
DCP-MTX will send a RS232 command to turn off the display connected to its
RS232 port when there’s no signal present after a defined Delay Time or turn it on
immediately when there’s active signal.
• Delay Time (min): Set the delay time of turning off the device after it receives
RS232 command from DCP-MTX. The time is 0 - 30 minutes.
• RS232 Wakeup Command: Key in a user-defined command for waking up the
device connected, then click the SAVE button.
• RS232 Standby Command: Key in a user-defined command for shutting down the
device connectedm, then click the SAVE button.
• RS232 Manual Control: Click to turn on or off the device manually.
3) RS232 Pass-through
The RS232 Pass-through section is for you to send RS232 command manually via Web
to control the device connected to the RS232 port.
• Baud Rate: Set the Baud Rate for the device connected to the RS232 port.
• Parity Bits: Set the Parity Bits for the device connected to the RS232 port.
• Data Bits: Set the Data Bits for the device connected to the RS232 port.
• Stop Bits: Set the Stop Bits for the device connected to the RS232 port.