17
USER MANUAL
DCP-MTX
7. CEC & RS232 AUTO CONTROL
DCP-MTX is embedded with a CEC controller and a RS232 controller. When CEC
/ RS232 Auto Control is switched on, DCP-MTX will detect the signal status and
send CEC / RS232 command to power on or off the display connected. CEC / RS232
Auto Control of DCP-MTX can be configured through Web UI or Telnet. For more
information, please refer to “8.2 WEB UI“and “8.3 TELNET”.
When CEC / RS232 Auto Control is enabled,
• DCP-MTX will automatically detect the status of input signal (HDMI, DP and VGA
when MYTURN is activated or HDBT when MYTURN is de-activated).
• DCP-MTX will power on the display (see two charts below):
1) If active input signal is present, DCP-MTX will send a CEC/RS232 command
to power on the display connected to HDMI OUT/RS232 port immediately.
MYTURN Activated
Detect for active input signal
(HDMI, DP, VGA)
1
Power on the display immediately
when active signal is detected
2
Display
DCP-MTX
HDMI
DP
VGA
HDBaseT
HDBaseT
Display
DCP-MTX
HDMI
DP
VGA
HDBaseT
HDBaseT
HDMI
DP
VGA
MYTURN De-activated
Detect for active input signal
(HDBT)
1
Power on the display immediately
when active signal is detected
2
Display
DCP-MTX
HDBaseT
HDBaseT
Display
DCP-MTX
HDBaseT
HDBaseT
HDBT
• DCP-MTX will power off the display (see two charts below):
1) If no input signal is present, DCP-MTX will send a CEC/RS232 command to
the display connected to HDMI OUT/RS232 port and start to countdown the
Delay Time till the display shuts down.