Telephone System Configuration
23
CSG SIP Communications Gateway Operation/Reference Guide
The
Audio Tuning
section will allow you to calibrate your analog ports for optimum performance. Please
ensure that your analog lines are plugged in before clicking the
Easy Calibrate
button. Your CSG must not
have any active calls for the calibration process to complete successfully on all analog ports. If you wish to
reset the calibration, click the
Reset Calibration
button.
In addition, an option to configure the gain level for each port will be listed. This option can be used to raise or
lower the audio level on your ports. Normally, you should not have to adjust your analog ports beyond the
initial calibration. Should you still need to fine tune your audio settings, please select one of the following:
Low
Soft
Normal
Loud
Louder
Once you have completed the Analog Trunk definition, click
Update
. For these changes to be completed, you
must reboot your CSG. Click
Options
on the left menu, select the
Reboot
tab, and then click
Reboot Now
to
reboot your appliance. Rebooting your CSG will terminate any active calls.
FIG. 15
Edit Analog Trunk
The Easy Calibration feature can take approximately 90 seconds per port to
complete.
Summary of Contents for CSG-500
Page 4: ...Safety Certification and Agency Approvals iv CSG SIP Communications Gateway ...
Page 8: ...viii CSG SIP Communications Gateway Operations Reference Guide Table of Contents ...
Page 12: ...CSG SIP Communications Gateway 4 CSG SIP Communications Gateway Operation Reference Guide ...
Page 22: ...Installation 14 CSG SIP Communications Gateway Operation Reference Guide ...
Page 83: ...Device Configuration 75 CSG SIP Communications Gateway Operation Reference Guide ...